The MAST motional Stark effect diagnostic
| dc.contributor.author | Conway, N. J. | |
| dc.contributor.author | De Bock, M. F. M. | |
| dc.contributor.author | Michael, C. A. | |
| dc.contributor.author | Walsh, M. J. | |
| dc.contributor.author | Carolan, P. G. | |
| dc.contributor.author | Hawkes, N. C. | |
| dc.contributor.author | Rachlew, E. | |
| dc.contributor.author | McCone, J. F. G. | |
| dc.contributor.author | Shibaev, S. | |
| dc.contributor.author | Wearing, G. | |
| dc.date.accessioned | 2015-12-07T03:07:16Z | |
| dc.date.available | 2015-12-07T03:07:16Z | |
| dc.date.issued | 2010 | |
| dc.date.updated | 2015-12-08T10:37:15Z | |
| dc.description.abstract | A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of ∼2.5 cm, and time resolution of ∼1 ms at angular noise levels of ∼0.5°. Conventional (albeit very narrow) interference filters isolate π or σ polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The π component is observed to be significantly stronger than σ, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on π. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses. | |
| dc.description.sponsorship | This work was funded partly by the United Kingdom Engineering and Physical Sciences Research Council under Grant No. P/G003955 and by the European Communities under the contract of association between Euratom and CCFE. | en_AU |
| dc.format | 7 pages | |
| dc.identifier.issn | 0034-6748 | en_AU |
| dc.identifier.uri | http://hdl.handle.net/1885/17059 | |
| dc.publisher | American Institute of Physics (AIP) | |
| dc.rights | © 2010 AIP Publishing. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. The following article appeared in Review of Scientific Instruments and may be found at http://doi.org/10.1063/1.3494254 http://publishing.aip.org/authors/copyright-reuse http://www.sherpa.ac.uk/romeo/issn/0034-6748 Author can archive publisher's version/PDF (Sherpa/Romeo as of 7/12/2015). | |
| dc.source | Review of Scientific Instruments | |
| dc.subject | motional Stark effect (MSE) | |
| dc.subject | MAST spherical tokamak | |
| dc.subject | 35 radial channels | |
| dc.subject | spatial resolution | |
| dc.subject | ∼2.5 cm | |
| dc.subject | time resolution | |
| dc.subject | ∼1 ms | |
| dc.subject | angular noise | |
| dc.subject | ∼0.5° | |
| dc.subject | π component | |
| dc.subject | σ | |
| dc.subject | atomic physics | |
| dc.title | The MAST motional Stark effect diagnostic | |
| dc.type | Journal article | |
| dcterms.dateAccepted | 2010-08-25 | |
| local.bibliographicCitation.issue | 10 | en_AU |
| local.bibliographicCitation.startpage | 10D738 | en_AU |
| local.contributor.affiliation | Conway, N.J., EURATOM/UKAEA Fusion Association, United Kingdom | en_AU |
| local.contributor.affiliation | De Bock, M F M, Eindhoven University of Technology, Netherlands | en_AU |
| local.contributor.affiliation | Michael, Clive, College of Physical and Mathematical Sciences, CPMS Research School of Physics and Engineering, Plasma Research Laboratory, The Australian National University | en_AU |
| local.contributor.affiliation | Walsh, M.J., ITER Organization, France | en_AU |
| local.contributor.affiliation | Carolan, P.G., EURATOM/UKAEA Fusion Association, United Kingdom | en_AU |
| local.contributor.affiliation | Hawkes, N C, EURATOM/CCFE Fusion Association, United Kingdom | en_AU |
| local.contributor.affiliation | Rachlew, E., EURATOM-VR Association, Sweden | en_AU |
| local.contributor.affiliation | McCone, J., University College, Association EURATOM-DCU Ireland. , Ireland | en_AU |
| local.contributor.affiliation | Shibaev, S, EURATOM/CCFE Fusion Association, United Kingdom | en_AU |
| local.contributor.affiliation | Wearing, G., EURATOM/CCFE Fusion Association, United Kingdom | en_AU |
| local.contributor.authoruid | u9617655 | en_AU |
| local.description.notes | Imported from ARIES. At the time of publication, Clive A. Michael was affiliated with EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB, United Kingdom. | en_AU |
| local.identifier.absfor | 020204 | en_AU |
| local.identifier.ariespublication | u4695161xPUB144 | en_AU |
| local.identifier.citationvolume | 81 | en_AU |
| local.identifier.doi | 10.1063/1.3494254 | en_AU |
| local.identifier.essn | 1089-7623 | en_AU |
| local.identifier.scopusID | 2-s2.0-78149426771 | |
| local.publisher.url | https://www.aip.org/ | en_AU |
| local.type.status | Published Version | en_AU |
Downloads
Original bundle
1 - 1 of 1
Loading...
- Name:
- 01_Conway_The_MAST_motional_Stark_effect_2010.pdf
- Size:
- 886.84 KB
- Format:
- Adobe Portable Document Format
- Description:
- Published Version
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 884 B
- Format:
- Item-specific license agreed upon to submission
- Description: