Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Measuring exposure to solar ultraviolet radiation using a dosimetric technique: Understanding participant compliance issues

Loading...
Thumbnail Image

Date

Authors

Sun, Jiandong
Harrison, Simone
Van Der Mei, Ingrid
Whiteman, David C
Mason, Rebecca
Nowak, Madeleine
Brodie, Alison
Kimlin, Michael
Lucas, Robyn

Journal Title

Journal ISSN

Volume Title

Publisher

American Society of Photobiology

Abstract

Personal ultraviolet dosimeters have been used in epidemiological studies to understand the risks and benefits of individuals' exposure to solar ultraviolet radiation (UVR). We investigated the types and determinants of noncompliance associated with a protocol for use of polysulphone UVR dosimeters. In the AusD Study, 1002 Australian adults (aged 18-75 years) were asked to wear a new dosimeter on their wrist each day for 10 consecutive days to quantify their daily exposure to solar UVR. Of the 10 020 dosimeters distributed, 296 (3%) were not returned or used (Type-I noncompliance) and other usage errors were reported for 763 (8%) returned dosimeters (Type-II noncompliance). Type-I errors were more common in participants with predominantly outdoor occupations. Type-II errors were reported more frequently on the first day of measurement; weekend days or rainy days; and among females; younger people; more educated participants or those with outdoor occupations. Half (50%) the participants reported a noncompliance error on at least 1 day during the 10-day period. However, 92% of participants had at least 7 days of usable data without any apparent noncompliance issues. The factors identified should be considered when designing future UVR dosimetry studies. Among 10 020 polysulphone UV dosimeters distributed in the AusD Study, the majority (89%) were returned with no reported issues, but 3% were not returned or used and 8% were returned with self-reported usage errors such as "missing some time," "covered by clothing," or "dosimeter got wet" that may potentially compromise the measurement quality. We found these noncompliance issues were more frequently reported on the first day of measurement; weekend days or rainy days; and among females; younger people; more educated participants or those with predominantly outdoor occupations. These factors should be considered when designing future UV dosimetry studies.

Description

Keywords

Citation

Source

Photochemistry and Photobiology

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31
abcd