Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Determining the Contribution of Retinotopic Discrimination to Localization Performance With a Suprachoroidal Retinal Prosthesis

dc.contributor.authorPetoe, Matt
dc.contributor.authorMcCarthy, Chris
dc.contributor.authorShivdasani, Mohit N
dc.contributor.authorSinclair, Nicholas C.
dc.contributor.authorScott, Adele
dc.contributor.authorAyton, Lauren N.
dc.contributor.authorBarnes, Nicholas (Nick)
dc.contributor.authorGuymer, Robyn
dc.contributor.authorAllen, P
dc.contributor.authorBlamey, Peter J.
dc.date.accessioned2020-12-20T20:56:30Z
dc.date.available2020-12-20T20:56:30Z
dc.date.issued2017
dc.date.updated2020-11-23T10:24:53Z
dc.description.abstractPurpose: With a retinal prosthesis connected to a head-mounted camera, subjects can perform low vision tasks using a combination of electrode discrimination and head-directed localization. The objective of the present study was to investigate the contribution of retinotopic electrode discrimination (perception corresponding to the arrangement of the implanted electrodes with respect to their position beneath the retina) to visual performance for three recipients of a 24-channel suprachoroidal retinal implant. Proficiency in retinotopic discrimination may allow good performance with smaller head movements, and identification of this ability would be useful for targeted rehabilitation. Methods: Three participants with retinitis pigmentosa performed localization and grating acuity assessments using a suprachoroidal retinal prosthesis. We compared retinotopic and nonretinotopic electrode mapping and hypothesized that participants with measurable acuity in a normal retinotopic condition would be negatively impacted by the nonretinotopic condition. We also expected that participants without measurable acuity would preferentially use head movement over retinotopic information. Results: Only one participant was able to complete the grating acuity task. In the localization task, this participant exhibited significantly greater head movements and significantly lower localization scores when using the nonretinotopic electrode mapping. There was no significant difference in localization performance or head movement for the remaining two subjects when comparing retinotopic to nonretinotopic electrode mapping. Conclusions: Successful discrimination of retinotopic information is possible with a suprachoroidal retinal prosthesis. Head movement behavior during a localization task can be modified using a nonretinotopic mapping. Behavioral comparisons using retinotopic and nonretinotopic electrode mapping may be able to highlight deficiencies in retinotopic discrimination, with a view to address these deficiencies in a rehabilitation environment. (ClinicalTrials.gov number, NCT01603576).
dc.format.mimetypeapplication/pdfen_AU
dc.identifier.issn1552-5783
dc.identifier.urihttp://hdl.handle.net/1885/217971
dc.language.isoen_AUen_AU
dc.publisherAssociation for Research in Vision and Opthalmology
dc.sourceInvestigative Ophthalmology and Visual Science
dc.titleDetermining the Contribution of Retinotopic Discrimination to Localization Performance With a Suprachoroidal Retinal Prosthesis
dc.typeJournal article
local.bibliographicCitation.issue7
local.bibliographicCitation.lastpage3239
local.bibliographicCitation.startpage3231
local.contributor.affiliationPetoe, Matt, Bionics Institute
local.contributor.affiliationMcCarthy, Chris, Swinburne University of Technology
local.contributor.affiliationShivdasani, Mohit N, Bionic Ear Institute
local.contributor.affiliationSinclair, Nicholas C., Bionics Institute
local.contributor.affiliationScott, Adele, College of Engineering and Computer Science, ANU
local.contributor.affiliationAyton, Lauren N., Centre for Eye Research
local.contributor.affiliationBarnes, Nicholas (Nick), College of Engineering and Computer Science, ANU
local.contributor.affiliationGuymer, Robyn, Centre for Eye Research Australia
local.contributor.affiliationAllen, P, The Royal Victorian Eye and Ear Hospital
local.contributor.affiliationBlamey, Peter J., Bionics Institute
local.contributor.authoruidScott, Adele, u2566368
local.contributor.authoruidBarnes, Nicholas (Nick), u4591576
local.description.notesImported from ARIES
local.identifier.absfor111302 - Optical Technology
local.identifier.ariespublicationa383154xPUB7481
local.identifier.citationvolume58
local.identifier.doi10.1167/iovs.16-21041
local.identifier.scopusID2-s2.0-85024407410
local.identifier.thomsonID000404959300044
local.type.statusPublished Version

Downloads

abcd