Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

High Vp/Vs ratio: Saturated cracks or anisotropy effects?

dc.contributor.authorWang, X-Q
dc.contributor.authorSchubnel, Alexandre
dc.contributor.authorFortin, Jerome
dc.contributor.authorDavid, Emmanuel
dc.contributor.authorGueguen, Yves
dc.contributor.authorGe, H-K
dc.date.accessioned2015-12-10T23:16:16Z
dc.date.issued2012
dc.date.updated2015-12-10T09:51:19Z
dc.description.abstractWe measured Vp/Vs ratios of thermally cracked Westerly granite, thermally cracked Carrara marble and 4% porosity Fontainebleau sandstone, for an effective mean pressure ranging from 2 to 95 MPa. Samples were fluid-saturated alternatively with argon gas and water (5 MPa constant pore pressure). The experimental results show that at ultrasonic frequencies, Vp/Vs ratio of water saturated specimen never exceeded 2.15, even at effective mean pressure as low as 2 MPa, or for a lithology for which the Poisson's ratio of minerals is as high as 0.3 (calcite). In order to check these results against theoretical models: we examine first a randomly oriented cracked medium (with dispersion but without anisotropy); and second a medium with horizontally aligned cracks (with anisotropy but without dispersion). The numerical results show that experimental data agree well with the first model: at high frequency, Vp/Vs ratios range from 1.6 to 1.8 in the dry case and from 1.6 to 2.2 in the saturated case. The second model predicts both Vp/Sv and Vp/Sh to vary from 1.2 to 3.5, depending on the raypath angle relative to the crack fabric. In addition, perpendicular to the crack fabric, a high Vp/Vs ratio is predicted in the absence of shear wave splitting. From these results, we argue the possibility that high Vp/Vs ratio (>2.2) as recently imaged by seismic tomography in subduction zones, may come from zones presenting important crack anisotropy. The cumulative effects of crack anisotropy and high pore fluid pressure are required to get Vp/Vs ratios above 2.2.
dc.identifier.issn0094-8276
dc.identifier.urihttp://hdl.handle.net/1885/64984
dc.publisherAmerican Geophysical Union
dc.sourceGeophysical Research Letters
dc.titleHigh Vp/Vs ratio: Saturated cracks or anisotropy effects?
dc.typeJournal article
local.bibliographicCitation.issue11
local.contributor.affiliationWang, X-Q, Key Laboratory of Seismic Observation and Geophysical Imaging
local.contributor.affiliationSchubnel, Alexandre, Ecole Normale Supérieure
local.contributor.affiliationFortin, Jerome, École Normale Supérieure
local.contributor.affiliationDavid, Emmanuel, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationGueguen, Yves, Ecole Normale Superieure
local.contributor.affiliationGe, H-K, China University of Petroleum
local.contributor.authoruidDavid, Emmanuel, u5384603
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor040499 - Geophysics not elsewhere classified
local.identifier.absseo970104 - Expanding Knowledge in the Earth Sciences
local.identifier.ariespublicationU3488905xPUB1032
local.identifier.citationvolume39
local.identifier.doi10.1029/2012GL051742
local.identifier.scopusID2-s2.0-84862178465
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Wang_High_Vp/Vs_ratio:_Saturated_2012.pdf
Size:
411.29 KB
Format:
Adobe Portable Document Format