Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

An accurate method for calibrating photoluminescence-based lifetime images on multi-crystalline silicon wafers

Loading...
Thumbnail Image

Date

Authors

Sio, Hang Cheong (Kelvin)
Phang, Sieu Pheng
Trupke, T
MacDonald, Daniel

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

We present a method for converting photoluminescence images into carrier lifetime images for silicon wafers with inhomogeneous lifetime distributions, such as multi-crystalline silicon wafers, based on a calibration factor extracted from a separate, homogeneous, mono-crystalline calibration wafer and simple optical modelling of the photoluminescence signal from both the calibration wafer and the test wafer. The method is applicable to planar wafers with uniform carrier profiles depth-wise. A multi-crystalline wafer is used to demonstrate the difference between the conventional calibration approach, where the photoluminescence signal is calibrated against a quasi-steady-state photoconductance measurement on the test sample itself, and our proposed method. The lifetimes calibrated by our method are consistent, in contrast with the lifetime calibrated by the conventional approach, in which the magnitude and injection-dependence of the lifetime is observed to be sensitive to the choice of reference area. The error in the conventional calibration method mainly originates from measurement artifacts in the quasi-steady-state photoconductance measurements on multi-crystalline wafers, which we propose to be mainly due to minority carrier trapping, radial sensitivity of the quasi-steady-state photoconductance sensor coil and overestimation of the carrier mobility sum. We also show that the proposed new method is effectively insensitive to the lifetime, doping density, reflectance and wafer thickness of the calibration wafer (provided it is below 500 μm).

Description

Keywords

Citation

Source

Solar Energy Materials and Solar Cells

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31
abcd