Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Recent advances in AMS of 36Cl with a 3-MV-tandem

Loading...
Thumbnail Image

Date

Authors

Martschini, M.
Forstner, O
Golser, Robin
Kutschera, Walter
Pavetich, Stefan
Priller, Alfred
Steier, P
Suter, M
Wallner, Anton

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

Accelerator mass spectrometry (AMS) of36Cl (t1/2 = 0.30 Ma) at natural isotopic concentrations requires high particle energies for the separation from the stable isobar36S and was so far the exclusive domain of tandem accelerators with at least 5 MV terminal voltage. Using terminal foil stripping and a detection setup consisting of a split-anode ionization chamber and an additional energy signal from a silicon strip detector, a36S suppression of >104 at 3 MV terminal voltage was achieved. To further increase the36S suppression energy loss straggling in various counter gases (C4H10, Ar-CH4 and C4H10-Ar) and the effect of "energy focusing" below the maximum of the Bragg curve was investigated. The comparison of experimental data with simulations and published data yielded interesting insights into the physics underlying the detectors. Energy loss, energy straggling and angular scattering determine the36S suppression. In addition, we improved ion source conditions, target backing materials and the cathode design with respect to sulfur output and cross contamination. These changes allow higher currents during measurement (35Cl- current ≈ 5 μA) and also increased the reproducibility. An injector to detector efficiency for36Cl ions of 8% (16% stripping yield for the 7+ charge state in the accelerator, 50%36Cl detection efficiency) was achieved, which can favorably be compared to other facilities. The memory effect in our ion source was also thoroughly investigated. Currently our measured blank value is36Cl/Cl ≈ 3 × 10-15 when samples with a ratio of 10-11 are used in the same sample wheel and36Cl/Cl ≈ 5 × 10-16 if measured together with samples with a ratio of 10-12 or below. This is in good agreement with the lowest so far published isotope ratios around 5 × 10-16 and demonstrates that 3 MV tandems can achieve the same sensitivity for36Cl as larger machines.

Description

Citation

Source

Nuclear Instruments and Methods in Physics Research Section B 269(24): ACCELERATORS IN APPLIED RESEARCH AND TECHNOLOGY. Proceedings of the 10th European Conference on Accelerators in Applied Research and Technology (ECAART10)

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31