Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Quantitative phase-contrast tomography using polychromatic radiation

dc.contributor.authorMyers, Glenn
dc.contributor.authorGureyev, Timur E
dc.contributor.authorPaganin, David M
dc.contributor.authorSiu, K W
dc.contributor.authorMayo, S.C.
dc.contributor.authorWilkins, S.W.
dc.coverage.spatialSan Deigo USA
dc.date.accessioned2015-12-10T22:40:31Z
dc.date.createdAugust 2008
dc.date.issued2008
dc.date.updated2016-02-24T11:55:46Z
dc.description.abstractWe discuss theoretical, experimental and numerical aspects of several new techniques for quantitative phase-contrast tomography using, for example, unfiltered radiation from a polychromatic X-ray microfocus source. The proposed algorithms allow one to reconstruct the three-dimensional distribution of complex refractive index in a sample consisting of one or more constituent materials, given one or more projection images per view angle. If the sample is weakly absorbing or consists predominantly of a single material, these reconstruction algorithms can be simplified and fewer projections may be required for an unambiguous quantitative reconstruction of the spatial distribution of the refractive index. In the case of weakly absorbing samples, the reconstruction algorithm is shown to be achromatic and stable with respect to high-spatial-frequency noise, in contrast to conventional tomography. A variation of the algorithm exploits the natural combination of binary tomography with a phase-retrieval method that makes explicit use of the single-material nature of the sample. Such consistent use of a priori knowledge dramatically reduces the number of required projections, implying significantly reduced dose and scanning time when compared to most alternative phase-contrast tomography methods. Experimental demonstrations are also given, using data from a point-projection X-ray microscope. The refractive index distribution, in test samples of both a polymer fibre scaffold and an adult mouse, is accurately reconstructed from polychromatic phase-contrast data. Applications of the new techniques to rapid non-destructive testing in materials science and biomedical imaging are considered.
dc.identifier.urihttp://hdl.handle.net/1885/57485
dc.publisherSPIE - The International Society for Optical Engineering
dc.relation.ispartofseriesDevelopments in X-Ray Tomography
dc.subjectKeywords: ABS resins; Computerized tomography; Diagnostic radiography; Growth (materials); Imaging systems; Light refraction; Materials; Materials testing; Medical imaging; Nondestructive examination; Optical properties; Refractive index; Refractometers; Repair; Re Binary tomography; Computed tomography; Diffraction; Phase contrast
dc.titleQuantitative phase-contrast tomography using polychromatic radiation
dc.typeConference paper
local.contributor.affiliationMyers, Glenn, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationGureyev, Timur E, CSIRO Materials Science and Engineering
local.contributor.affiliationPaganin, David M, Monash University
local.contributor.affiliationSiu, K W, Monash University
local.contributor.affiliationMayo, S.C., CSIRO
local.contributor.affiliationWilkins, S.W., CSIRO
local.contributor.authoruidMyers, Glenn, u4703841
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.description.refereedYes
local.identifier.absfor020501 - Classical and Physical Optics
local.identifier.absfor080106 - Image Processing
local.identifier.absfor020402 - Condensed Matter Imaging
local.identifier.ariespublicationu9210271xPUB402
local.identifier.doi10.1117/12.795999
local.identifier.scopusID2-s2.0-56249141457
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Myers_Quantitative_phase-contrast_2008.pdf
Size:
890.29 KB
Format:
Adobe Portable Document Format