High resolution multifocal pupillographic objective perimetry in glaucoma

dc.contributor.authorCarle, Corinne
dc.contributor.authorJames, Andrew
dc.contributor.authorKolic, Maria
dc.contributor.authorLoh, Yik-Wen
dc.contributor.authorMaddess, Ted
dc.date.accessioned2015-12-08T22:25:44Z
dc.date.issued2011
dc.date.updated2016-02-24T11:40:52Z
dc.description.abstractPURPOSE. The recent development of an objective and noninvasive perimetric technique using pupillary responses to sparse multifocal visual stimuli shows promise for the assessment of visual function in glaucoma. This study assesses the sensitivity and specificity of four variants of dichoptic multifocal pupillographic objective perimetry (mfPOP) with a highresolution, 40-region/field stimulus. METHODS. Nineteen normal subjects and 17 with open-angle glaucoma were tested with four 4-minute stimulus protocols, presented in eight segments of 30 seconds each. Achromatic multifocal stimuli comprised 40 test regions per eye arranged in a four-ring dartboard layout subtending 60° of visual field. Background luminance was 10 cd/m2 with active stimulus regions displaying steady or flickered stimuli at 290 cd/m2. Stimulus durations were between 33 and 150 ms, mean intervals between presentations to each test region ranged from 1 to 16 seconds. Fixation was monitored in real time. RESULTS. Longer mean intervals and durations resulted in better diagnostic performance. Best results were obtained with 150-ms flickered stimuli and a discriminant function that incorporated both amplitude and width of responses: ROC area under the curve 0.86 ± 0.05 (mean ± SE) across all visual field severities, (n =34) and 1.00 ± 0.00 for moderate and severe fields (n= 10). CONCLUSIONS. mfPOP produces separate information on response delay and afferent and efferent defects at every point in the field. The diagnostic accuracy of the 40-region, 150-ms stimulus is comparable to that of commonly used subjective perimeters and encourages further investigation of this technique.
dc.identifier.issn1552-5783
dc.identifier.urihttp://hdl.handle.net/1885/33576
dc.publisherAssociation for Research in Vision and Opthalmology
dc.rightsAuthor/s retain copyrighten_AU
dc.sourceInvestigative Ophthalmology and Visual Science
dc.subjectKeywords: adult; article; clinical article; controlled study; critical flicker fusion; diagnostic accuracy; discriminant analysis; disease severity; evoked visual response; eye fixation; female; human; luminance; male; multifocal pupillographic objective perimetry;
dc.titleHigh resolution multifocal pupillographic objective perimetry in glaucoma
dc.typeJournal article
dcterms.accessRightsOpen Accessen_AU
local.bibliographicCitation.issue1
local.bibliographicCitation.startpage28
local.contributor.affiliationCarle, Corinne, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationJames, Andrew, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationKolic, Maria, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationLoh, Yik-Wen, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationMaddess, Ted, College of Medicine, Biology and Environment, ANU
local.contributor.authoruidCarle, Corinne, u4117988
local.contributor.authoruidJames, Andrew, u8607703
local.contributor.authoruidKolic, Maria, u4385340
local.contributor.authoruidLoh, Yik-Wen, u4182554
local.contributor.authoruidMaddess, Ted, u8103614
local.description.notesImported from ARIES
local.identifier.absfor111301 - Ophthalmology
local.identifier.absseo920203 - Diagnostic Methods
local.identifier.absseo920107 - Hearing, Vision, Speech and Their Disorders
local.identifier.ariespublicationu8611701xPUB103
local.identifier.citationvolume52
local.identifier.doi10.1167/iovs.10-5737
local.identifier.scopusID2-s2.0-79952458172
local.identifier.thomsonID000287097400033
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
01_Carle_High_resolution_multifocal_2011.pdf
Size:
483.02 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
02_Carle_High_resolution_multifocal_2011.pdf
Size:
334.24 KB
Format:
Adobe Portable Document Format