Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Surgical Treatment of Pelvic Discontinuity: A Systematic Review and Meta-Analysis

Loading...
Thumbnail Image

Date

Authors

Perriman, Diana
Szczepanski, Jason R.
Smith, Paul

Journal Title

Journal ISSN

Volume Title

Publisher

Journal of Bone and Joint Surgery

Abstract

Background: Pelvic discontinuity is a rare condition that is treated with a range of implant constructs. However, surgical failure rates are high, and outcome data are inconsistent. It is therefore difficult to gain a clear picture of whether recently developed constructs (antiprotrusio cage [APC], cup-cage, custom triflange, and porous metal) provide better outcomes in terms of mechanical failure and complications in the short to long terms. This study investigated the failure and complication rates associated with cage constructs and porous metal technologies. Methods: A systematic review and meta-analysis were performed according to the Meta-analysis Of Observational Studies in Epidemiology (MOOSE) guidelines to evaluate the studies showing pelvic discontinuity in revision total hip arthroplasty. Data retrieved included the intervention performed, length of follow-up, mechanical failure, and other complication rates (dislocation, infection, neurological, loosening, migration). Study quality was assessed with the Methodological Index for Non-Randomized Studies (MINORS) instrument. Pooled mechanical failure and complication rates were calculated using MetaXL 5.3. Results: None of the included 30 articles (n = 585 hips) were of high quality. The meta-analyses revealed a mechanical failure rate of 14% for all constructs combined. Custom triflange (5%) and cup-cage (7%) had the lowest mechanical failure rates compared with the commonly used APC (25%) and porous metal (12%). The overall other complication rate was 28%, with cup-cage lower at 21% compared with APC (34%) and custom triflange (28%). Long-term evidence investigating both interventions and porous metal technology is limited. Conclusions: Mechanical failure rates for cup-cage and custom triflange were lowest. The other complication rate for cup-cage was lower than the pooled average. The study quality was limited, indicating a need for better studies and/or a registry. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Description

Keywords

Citation

Source

JBJS Reviews

Book Title

Entity type

Access Statement

License Rights

Restricted until

2099-12-31