Accelerator mass spectrometry with the 14UD accelerator at the Australian National University

dc.contributor.authorFifield, L Keith
dc.contributor.authorTims, Stephen
dc.contributor.authorFujioka, Toshiyuki
dc.contributor.authorHoo, Wee T
dc.contributor.authorEverett, Sarah
dc.date.accessioned2015-12-10T22:38:52Z
dc.date.issued2010
dc.date.updated2016-02-24T10:38:46Z
dc.description.abstractThe present status of the AMS activities at the Australian National University is described. Particular attention is paid to methods and equipment that have evolved substantially since earlier reports.
dc.identifier.issn0168-583X
dc.identifier.urihttp://hdl.handle.net/1885/56919
dc.publisherElsevier
dc.sourceNuclear Instruments and Methods in Physics Research: Section B
dc.subjectKeywords: Accelerator mass spectrometry; Australian National University; Carbon 14; Present status; Beryllium; Chlorine; Particle accelerators; Plutonium; Mass spectrometry Accelerator mass spectrometry; Beryllium-10; Carbon-14; Chlorine-36; Plutonium
dc.titleAccelerator mass spectrometry with the 14UD accelerator at the Australian National University
dc.typeJournal article
local.bibliographicCitation.lastpage862
local.bibliographicCitation.startpage858
local.contributor.affiliationFifield, L Keith, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationTims, Stephen, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationFujioka, Toshiyuki, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationHoo, Wee T, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationEverett, Sarah, College of Physical and Mathematical Sciences, ANU
local.contributor.authoremailu8100341@anu.edu.au
local.contributor.authoruidFifield, L Keith, u8100341
local.contributor.authoruidTims, Stephen, u4013304
local.contributor.authoruidFujioka, Toshiyuki, u3923657
local.contributor.authoruidHoo, Wee T, u4347377
local.contributor.authoruidEverett, Sarah, u4088427
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor029904 - Synchrotrons; Accelerators; Instruments and Techniques
local.identifier.ariespublicationu4155331xPUB380
local.identifier.citationvolume268
local.identifier.doi10.1016/j.nimb.2009.10.049
local.identifier.scopusID2-s2.0-77949902050
local.identifier.thomsonID000277462300045
local.identifier.uidSubmittedByu4155331
local.type.statusPublished Version