Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Comparing a parallel PERG, automated perimetry and frequency doubling thresholds.

dc.contributor.authorMaddess, Ted
dc.contributor.authorJames, Andrew
dc.contributor.authorGoldberg, Ivan
dc.contributor.authorWine, Stephen
dc.contributor.authorDobinson, Jeffrey
dc.date.accessioned2015-12-13T23:16:00Z
dc.date.available2015-12-13T23:16:00Z
dc.date.issued2000
dc.date.updated2015-12-12T08:46:13Z
dc.description.abstractPURPOSE. A pattern electroretinogram (PERG) simultaneously displaying the frequency-doubling (FD) illusion in nine parts of the visual field was compared with two other methods for ability to detect glaucoma. This multiregion FD PERG (MFP) was compared with results from achromatic automated perimetry and psychophysical tests using FD stimuli. METHODS. MFP data were compared with that from the Humphrey Field Analyser (HFA; Humphrey, San Leandro, CA) 24-2 program. Contrast thresholds were also determined in different visual field locations for FD stimuli. Thin-plate spline methods were used to derive comparisons from the tests, each of which sampled the visual field differently. RESULTS. Significant correlation with HFA could be obtained, providing seven to nine (of nine) MFP amplitudes were themselves significant. Evidence showed that both the psychophysical tests using FD stimuli and the MFP detect glaucomatous damage not detected by the HFA. CONCLUSIONS. The comparisons between HFA perimetry, the MFP, and FD thresholds indicate that both FD-based tests quantify a form of diffuse loss in early glaucoma as well as the scotomas of later glaucoma.
dc.identifier.issn1552-5783
dc.identifier.urihttp://hdl.handle.net/1885/89187
dc.publisherAssociation for Research in Vision and Opthalmology
dc.sourceInvestigative Ophthalmology and Visual Science
dc.subjectKeywords: article; clinical article; controlled study; diagnostic test; electroretinogram; glaucoma; human; intermethod comparison; perimetry; priority journal; scotoma; visual field; visual illusion; visual stimulation; visual threshold; Electroretinography; Glauc
dc.titleComparing a parallel PERG, automated perimetry and frequency doubling thresholds.
dc.typeJournal article
local.bibliographicCitation.lastpage3823
local.bibliographicCitation.startpage3827
local.contributor.affiliationMaddess, Ted, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationJames, Andrew, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationGoldberg, Ivan, Prince of Wales Hospital
local.contributor.affiliationWine, Stephen, Prince Alfred Hospital
local.contributor.affiliationDobinson, Jeffrey, Prince Alfred Hospital
local.contributor.authoruidMaddess, Ted, u8103614
local.contributor.authoruidJames, Andrew, u8607703
local.description.notesImported from ARIES
local.description.refereedYes
local.identifier.absfor111303 - Vision Science
local.identifier.ariespublicationMigratedxPub19132
local.identifier.citationvolume41
local.identifier.scopusID2-s2.0-0033764309
local.type.statusPublished Version

Downloads