Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Multifocal pupillographic visual field testing in glaucoma

Loading...
Thumbnail Image

Date

Authors

Maddess, Ted
Bedford, Suzanne
Goh, Xin-Lin
James, Andrew

Journal Title

Journal ISSN

Volume Title

Publisher

Blackwell Science Asia

Abstract

Purpose: This preliminary study investigated a means of concurrently assessing the visual field defects of both eyes by recording pupillary responses to multifocal stimuli. Methods: Twenty normal subjects and 26 primary open angle glaucoma patients, age and sex matched, were examined by slit-lamp, Humphrey Field Analyser II achromatic 24-2 perimetry and fundus photography. The patients had moderate to severe fields in at least one eye. Two stereoscopically arranged displays presented an array of 24 stimulus regions per eye extending from fixation to 30 degrees eccentricity. Pupil responses were recorded by video cameras under infrared illumination. Four stimulus conditions were tested: each stimulus region containing either a single or a 2 × 2 array of patches, presented either steadily for 133 ms or flickered at 15 Hz for 266 ms. Mean presentation rate was 1/s/region. The 4-min duration stimuli were presented in 8 segments of 30 s. Segments did not need to be repeated unless more than 15% of a segment record was lost as a result of blinks or fixation losses. Results: The 48 stimuli produced 96 direct and consensual responses per subject. The single patch, non-flickered stimulus condition produced the best diagnostic performance, an area under the curve of 84%. The contraction amplitudes for that stimulus gave a median z-score of 3.2. Conclusions: The method produced diagnostic accuracy approaching that of automated perimetry, but unlike perimetry provides standard errors for every point in each field as well as information on response delay and efferent defects. Only one pupil needs to function to measure both visual fields.

Description

Citation

Source

Clinical and Experimental Ophthalmology

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31
abcd