Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Adequacy and Diagnostic Accuracy of Aspiration vs. Capillary Fine Needle Thyroid Biopsies

dc.contributor.authorAmaral de Carvalho, Gisah
dc.contributor.authorDa Paz Filho, Gilberto
dc.contributor.authorCavalcanti, Teresa Cristina Santos
dc.contributor.authorGraf, Hans
dc.date.accessioned2015-12-07T22:41:10Z
dc.date.issued2009
dc.date.updated2016-02-24T10:16:48Z
dc.description.abstractThyroid nodules can be biopsied by fine needle aspiration (FNA) or fine needle capillary (FNC) biopsies. However, there is controversy on whether one technique is superior to another. In a randomized cytopathologist-blinded cross-sectional study, 260 patients (238 females, age 43.2 ± 12.6) with nodular (82.7%) and diffuse goiter (17.3%) underwent 520 FNAs and 520 FNCs (not guided by ultrasound). Smears were scored for sample adequacy, and diagnosed as malignant, benign, suspicious, or nondiagnostic. Diagnostic accuracy was calculated based on the histological findings of 58 patients submitted to surgery. Intra-technique diagnostic accuracy and sample adequacy was seen in all samples. FNA and FNC provided similar cytological diagnosis, respectively (benign: 75.8% vs. 74.2%, p = 0.600; malignant: 3.8% vs. 3.8%, p = 0.871; suspicious: 10.4% vs. 10.8%, p = 0.913; and nondiagnostic: 10.0% vs. 11.2%, p = 0.598). Adequacy scores were similar by FNA (7.94 ± 2.84) and FNC (7.96 ± 2.81, p = 0.909). The same proportion of adequate or superior samples was seen in both techniques (91.6%). Sensitivity was equal to 85.7% for FNA and 100% for FNC. Similarly, specificity was 100% for both techniques. FNA and FNC provide the similar sample adequacy and diagnostic accuracy. The choice of technique should be based on the operator's personal preferences and experience.
dc.identifier.issn1046-3976
dc.identifier.urihttp://hdl.handle.net/1885/24193
dc.publisherHumana Press Inc.
dc.sourceEndocrine Pathology
dc.subjectKeywords: adult; article; aspiration biopsy; clinical trial; controlled clinical trial; cross-sectional study; cytopathology; diagnostic accuracy; diffuse goiter; female; goiter; histopathology; human; human tissue; major clinical study; male; needle biopsy; nodula Aspiration; Biopsy; Capillary; Fine needle; Goiter; Nodule; Thyroid
dc.titleAdequacy and Diagnostic Accuracy of Aspiration vs. Capillary Fine Needle Thyroid Biopsies
dc.typeJournal article
local.bibliographicCitation.issue4
local.bibliographicCitation.lastpage8
local.bibliographicCitation.startpage204
local.contributor.affiliationAmaral de Carvalho, Gisah, Federal University of Parana
local.contributor.affiliationDa Paz Filho, Gilberto, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationCavalcanti, Teresa Cristina Santos, Federal University of Parana
local.contributor.affiliationGraf, Hans, Federal University of Parana
local.contributor.authoruidDa Paz Filho, Gilberto, u4763468
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor110306 - Endocrinology
local.identifier.ariespublicationu3526593xPUB31
local.identifier.citationvolume20
local.identifier.doi10.1007/s12022-009-9092-0
local.identifier.scopusID2-s2.0-70449472866
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Amaral de Carvalho_Adequacy_and_Diagnostic_2009.pdf
Size:
140.27 KB
Format:
Adobe Portable Document Format
abcd