Open Research will be updating the system on Tuesday, 14 July 2026, from 8:15 to 9:00 AM. We apologise for any inconvenience caused.

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

An upgrade of the magnetic diagnostic system of the DIII-D tokamak for non-axisymmetric measurements

Loading...
Thumbnail Image

Date

Authors

King, J. D
Strait, E. J
Boivin, R. L
Taussig, D.
Watkins, M. G
Hanson, J. M
Logan, N. C
Paz-Soldan, C.
Pace, D. C
Shiraki, D.

Journal Title

Journal ISSN

Volume Title

Publisher

American Institute of Physics (AIP)

Abstract

The DIII-D tokamak magnetic diagnostic system [E. J. Strait, Rev. Sci. Instrum. 77, 023502 (2006)] has been upgraded to significantly expand the measurement of the plasma response to intrinsic and applied non-axisymmetric "3D" fields. The placement and design of 101 additional sensors allow resolution of toroidal mode numbers 1 ≤ n ≤ 3, and poloidal wavelengths smaller than MARS-F, IPEC, and VMEC magnetohydrodynamic model predictions. Small 3D perturbations, relative to the equilibrium field (10(-5) < δB/B0 < 10(-4)), require sub-millimeter fabrication and installation tolerances. This high precision is achieved using electrical discharge machined components, and alignment techniques employing rotary laser levels and a coordinate measurement machine. A 16-bit data acquisition system is used in conjunction with analog signal-processing to recover non-axisymmetric perturbations. Co-located radial and poloidal field measurements allow up to 14.2 cm spatial resolution of poloidal structures (plasma poloidal circumference is ~500 cm). The function of the new system is verified by comparing the rotating tearing mode structure, measured by 14 BP fluctuation sensors, with that measured by the upgraded B(R) saddle loop sensors after the mode locks to the vessel wall. The result is a nearly identical 2/1 helical eigenstructure in both cases.

Description

Citation

Source

Review of Scientific Instruments

Book Title

Entity type

Access Statement

License Rights

Restricted until

Downloads

abcd