Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Volumetrics of the caudate nucleus: Reliability and validity of a new manual tracing protocol

Loading...
Thumbnail Image

Date

Authors

Looi, Jeffrey
Lindberg, Olof
Liberg, Benny
Tatham, Vanessa
Kumar, Rajeev
Maller, Jerome
Millard, Ellen
Sachdev, Perminder Singh
Hogberg, Goran
Pagani, Marco

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

Our aim was to develop a reliable and valid manual segmentation protocol for tracing the caudate nucleus in MRI for volumetric and, potentially, shape analysis of the caudate. Using the protocol, two inter- and intra-rater reliability studies were conducted using five different raters on two different image analysis platforms (ANALYZE, Mayo Biomedical Imaging Resource, Rochester MN, USA, and HERMES, Nuclear Diagnostics AB, Stockholm, Sweden). Reference images for the detailed protocol are described. Two studies were performed. In study 1, the intra-rater class correlation ICC(1,1) for an experienced rater (JCLL) using this protocol for caudate nucleus volumes was evaluated by repeating right and left caudate measurements on 10 scans (20 comparisons) and was 0.972. The inter-rater class correlation ICC(1,k) with OL was 0.922 on 5 scans (10 comparisons) and with BL was 0.960 on 5 scans (10 comparisons). In study 2, VT obtained an intra-rater class correlation of 0.9 on 5 scans (involving 10 comparisons, e.g. right and left caudate). The inter-rater class correlation ICC(1,k) was 0.988 on 5 scans (again involving 10 comparisons) with EM. We therefore developed a novel, reliable and reference image-based, method of outlining the caudate nucleus on axial MRI scans, usable in two different image analysis laboratories, across two different sets number of tracers reliably, and across software platforms. This method is therefore potentially usable for any image analysis package capable of displaying and measuring outlined voxels from MRI brain scans.

Description

Citation

Source

Psychiatry Research: Neuroimaging

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31