Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Stimulus Parameters for Multifocal Pupillographic Objective Perimetry

dc.contributor.authorJames, Andrew
dc.contributor.authorKolic, Maria
dc.contributor.authorBedford, Suzanne
dc.contributor.authorMaddess, Ted
dc.date.accessioned2015-12-10T21:57:28Z
dc.date.issued2011
dc.date.updated2016-02-24T11:41:24Z
dc.description.abstractPurpose: We compared the diagnostic power of 10 stimulus variants that assessed the visual fields of both eyes by recording pupillary responses to multifocal stimuli. The 10 variants comprised 6 initial tests, and 4 subsequent variants whose design was informed by the initial results. Methods: Two study groups containing 16 normal and 22 primary open angle glaucoma subjects, and 15 normal and 20 primary open angle glaucoma subjects had their diagnostic status verified by a slit-lamp investigation, applanation tonometry, 3 forms of perimetry, and Stratus OCT. Stereoscopically arranged displays presented multifocal stimulus arrays having 24 stimulus regions/eye within the central 60 degrees. Pupil responses were recorded by video cameras under infrared illumination. The 10 stimulus conditions varied in presentation rate, duration, stimulus luminance, and flicker rate. Stimuli were 4 minutes in duration, presented in 8 segments of 30 seconds. Up to 15% of the data of a segment could be lost owing to blinks and fixation losses without repeating the segment. Results: Each recording gave 96 direct and consensual responses/subject. The best performing stimulus method gave a sensitivity of 1.0±0.0 (mean±SE) for moderate and severe glaucomatous fields combined at a false positive rate of 0.05. Median signal to noise ratios for peak response amplitude expressed as t-statistics exceeded 4 for several variants. Conclusions: Stimulus delivery rates of about 1 presentation/region/s and test luminance around 150 cd/m performed best diagnostically. Unlike automated perimetry, the mfPOP method provides information on response delays and afferent and efferent defects at each region of the visual field.
dc.identifier.issn1057-0829
dc.identifier.urihttp://hdl.handle.net/1885/39794
dc.publisherLippincott Williams & Wilkins
dc.sourceJournal of Glaucoma
dc.subjectKeywords: adult; amplitude modulation; article; blinking; clinical article; controlled clinical trial; controlled study; diagnostic value; eye fixation; female; human; luminance; male; multifocal pupillographic objective perimetry; open angle glaucoma; optical cohe dichoptic; glaucoma; multifocal; perimetry; pupillography
dc.titleStimulus Parameters for Multifocal Pupillographic Objective Perimetry
dc.typeJournal article
local.contributor.affiliationJames, Andrew, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationKolic, Maria, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationBedford, Suzanne, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationMaddess, Ted, College of Medicine, Biology and Environment, ANU
local.contributor.authoruidJames, Andrew, u8607703
local.contributor.authoruidKolic, Maria, u4385340
local.contributor.authoruidBedford, Suzanne, u9213012
local.contributor.authoruidMaddess, Ted, u8103614
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor111301 - Ophthalmology
local.identifier.absseo920107 - Hearing, Vision, Speech and Their Disorders
local.identifier.absseo920203 - Diagnostic Methods
local.identifier.ariespublicationu8611701xPUB183
local.identifier.citationvolumePublished ahead of print 26 May 2011
local.identifier.doi10.1097/IJG.0b013e31821e8413
local.identifier.scopusID2-s2.0-84871088989
local.identifier.thomsonID000311898700001
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_James_Stimulus_Parameters_for_2011.pdf
Size:
321.06 KB
Format:
Adobe Portable Document Format