Astronomical calibration of Ar-40/Ar-39 reference minerals using high-precision, multi-collector (ARGUSVI) mass spectrometry
Loading...
Date
Authors
Phillips, David
Matchan, Erin
Honda, Masahiko
Kuiper, K. F.
Journal Title
Journal ISSN
Volume Title
Publisher
Pergamon Press Ltd.
Abstract
The new generation of multi-collector mass spectrometers (e.g. ARGUSVI) permit ultra-high precision (<0.1%) Ar-40/Ar-39 geochronology of rocks and minerals. At the same time, the Ar-40/Ar-39 method is limited by relatively large uncertainties (>1%) in K-40 decay constants and the ages of natural reference minerals that form the basis of the technique. For example, reported ages for widely used Ar-40/Ar-39 reference materials, such as the ca. 28 Ma Fish Canyon Tuff sanidine (FCTs) and the ca. 1.2 Ma Alder Creek Rhyolite sanidine (ACRs), vary by >1%. Recent attempts to independently calibrate these reference minerals have focused on K-Ar analyses of the same minerals and inter-comparisons with astronomically tuned tephras in sedimentary sequences and U-Pb zircon ages from volcanic rocks. Most of these studies used older generation (effectively single-collector) mass spectrometers that employed peak-jumping analytical methods to acquire Ar-40/Ar-39 data. In this study, we reassess the inter-calibration and ages of commonly used Ar-40/Ar-39 reference minerals Fish Canyon Tuff sanidine (FCTs), Alder Creek Rhyolite sanidine (ACRs) and Mount Dromedary biotite (MD2b; equivalent to GA-1550 biotite), relative to the astronomically tuned age of A1 Tephra sanidine (A1Ts), Faneromeni section, Crete (Rivera et al., 2011), using a multi-collector ARGUSVI mass spectrometer. These analyses confirm the exceptional precision capability (<0.1%) of this system, compared to most previous studies. All sanidine samples (FCTs, ACRs and A1Ts) exhibit discordant Ar-40/Ar-39 step-heating spectra, with generally monotonically increasing ages (similar to 1% gradients). The similarity in these patterns, mass-dependent fractionation modeling, and results from step-crushing experiments on FCTs, which yield younger apparent ages, suggest that the discordance may be due to a combination of recoil loss and redistribution of (ArK)-Ar-39 and isotope mass fractionation. In contrast to our previous inferences, these results imply that the sanidine samplesAre suitable Ar-40/Ar-39 reference materials, provided appropriate corrections Are included for differential recoil loss of 39ArK and contributions from xenocrysts/antecrysts can be resolved. Relative to an age of 6.943 +/- 0.005 Ma for A1Ts, we calculate astronomically tuned ages for FCTs, ACRs and MD2b of 28.126 +/- 0.019 (0.066%) Ma, 1.18144 +/- 0.00068 (0.058%) Ma and 99.125 +/- 0.076 (0.077%) Ma, respectively (95% internal errors). These results are consistent with recent U-238/Pb-206 age data from these localities, but are marginally younger (similar to 0.2%) than previous Ar-40/Ar-39 ages inter-calibrated with astronomically tuned tephra from the Mediterranean, and distinctly younger (0.6%) than results optimized against a broad array of U-238/(206) Pb zircon ages. Consideration of published and assumed recoil loss 39ArK proportions (0.18-0.40%), yields recoil-corrected age estimates of 28.187 +/- 0.019 Ma, 1.18404 +/- 0.00068 Ma and 99.204 +/- 0.076 Ma, respectively. This comparison indicates inherent uncertainties of >0.1% in the Ar-40/Ar-39 ages of reference minerals without consideration of recoil artefacts, thus limiting the benefits of high precision multi-collector analyses.
Description
Citation
Collections
Source
Geochimica et Cosmochimica Acta
Type
Book Title
Entity type
Access Statement
License Rights
Restricted until
2099-12-31
Downloads
File
Description