Inter-laboratory study for the certification of trace elements in seawater certified reference materials NASS-7 and CASS-6

dc.contributor.authorYang, Lu
dc.contributor.authorNadeau, Kenny
dc.contributor.authorMeija, Juris
dc.contributor.authorGrinberg, Patricia
dc.contributor.authorPagliano, Enea
dc.contributor.authorArdini, Francisco
dc.contributor.authorGrotti, Marco
dc.contributor.authorSchlosser, Christian
dc.contributor.authorStreu, Peter
dc.contributor.authorAchterberg, Eric P
dc.contributor.authorEllwood, Michael
dc.date.accessioned2019-07-08T06:21:54Z
dc.date.issued2018-05-02
dc.date.updated2019-03-31T07:17:52Z
dc.description.abstractCertification of trace metals in seawater certified reference materials (CRMs) NASS-7 and CASS-6 is described. At the National Research Council Canada (NRC), column separation was performed to remove the seawater matrix prior to the determination of Cd, Cr, Cu, Fe, Pb, Mn, Mo, Ni, U, V, and Zn, whereas As was directly measured in 10-fold diluted seawater samples, and B was directly measured in 200-fold diluted seawater samples. High-resolution inductively coupled plasma mass spectrometry (HR-ICPMS) was used for elemental analyses, with double isotope dilution for the accurate determination of B, Cd, Cr, Cu, Fe, Pb, Mo, Ni, U, and Zn in seawater NASS-7 and CASS-6, and standard addition calibration for As, Co, Mn, and V. In addition, all analytes were measured using standard addition calibration with triple quadrupole (QQQ)-ICPMS to provide a second set of data at NRC. Expert laboratories worldwide were invited to contribute data to the certification of trace metals in NASS-7 and CASS-6. Various analytical methods were employed by participants including column separation, co-precipitation, and simple dilution coupled to ICPMS detection or flow injection analysis coupled to chemiluminescence detection, with use of double isotope dilution calibration, matrix matching external calibration, and standard addition calibration. Results presented in this study show that majority of laboratories have demonstrated their measurement capabilities for the accurate determination of trace metals in seawater. As a result of this comparison, certified/reference values and associated uncertainties were assigned for 14 elements in seawater CRMs NASS-7 and CASS-6, suitable for the validation of methods used for seawater analysis.en_AU
dc.format.mimetypeapplication/pdfen_AU
dc.identifier.citationYang, L., Nadeau, K., Meija, J. et al. Anal Bioanal Chem (2018) 410: 4469. https://doi.org/10.1007/s00216-018-1102-yen_AU
dc.identifier.issn1618-2642en_AU
dc.identifier.urihttp://hdl.handle.net/1885/164399
dc.language.isoen_AUen_AU
dc.publisherSpringer Berlin Heidelbergen_AU
dc.rights© 2018 Crownen_AU
dc.sourceAnalytical and Bioanalytical Chemistryen_AU
dc.source.urihttps://doi.org/10.1007/s00216-018-1102-yen_AU
dc.subjectDissolved trace metalsen_AU
dc.subjectSeawateren_AU
dc.subjectCertified reference materialen_AU
dc.subjectIsotope dilutionen_AU
dc.subjectHR-ICPMSen_AU
dc.subjectFlow injection analysisen_AU
dc.subjectStandard addition calibrationen_AU
dc.titleInter-laboratory study for the certification of trace elements in seawater certified reference materials NASS-7 and CASS-6en_AU
dc.typeJournal articleen_AU
dcterms.dateAccepted2018-04-20
local.bibliographicCitation.issue18en_AU
local.contributor.affiliationYang, Lu, National Research Council Canadaen_AU
local.contributor.affiliationNadeau, Kenny, National Research Council Canadaen_AU
local.contributor.affiliationMeija, Juris, National Research Council Canadaen_AU
local.contributor.affiliationGrinberg, Patricia, National Research Council Canadaen_AU
local.contributor.affiliationPagliano, Enea, National Research Council Canadaen_AU
local.contributor.affiliationArdini, Francisco, University of Genoaen_AU
local.contributor.affiliationGrotti, Marco, University of Genoaen_AU
local.contributor.affiliationSchlosser, Christian, GEOMAR - Helmholtz Centre for Ocean Researchen_AU
local.contributor.affiliationStreu, Peter, GEOMAR - Helmholtz Centre for Ocean Researchen_AU
local.contributor.affiliationAchterberg, Eric P, GEOMAR - Helmholtz Centre for Ocean Researchen_AU
local.contributor.affiliationEllwood, Michael, College of Science, ANUen_AU
local.contributor.authoruidEllwood, Michael, u4346971en_AU
local.description.embargo2037-12-31
local.description.notesImported from ARIESen_AU
local.identifier.absfor030199 - Analytical Chemistry not elsewhere classifieden_AU
local.identifier.absseo961199 - Physical and Chemical Conditions of Water not elsewhere classifieden_AU
local.identifier.ariespublicationa383154xPUB10389en_AU
local.identifier.citationvolume410en_AU
local.identifier.doi10.1007/s00216-018-1102-yen_AU
local.identifier.scopusID2-s2.0-85049140972
local.publisher.urlwww.springer.comen_AU
local.type.statusPublished Versionen_AU

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Yang_Inter-laboratory_study_for_the_2018.pdf
Size:
868.12 KB
Format:
Adobe Portable Document Format