Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

The nocturnal acoustical intensity of the intensive care environment: An observational study

dc.contributor.authorDelaney, Lori
dc.contributor.authorCurrie, Marian
dc.contributor.authorHuang, Carol
dc.contributor.authorLopez, Violeta
dc.contributor.authorLitton, Edward
dc.contributor.authorVan Haren, Frank
dc.date.accessioned2021-01-13T23:38:24Z
dc.date.available2021-01-13T23:38:24Z
dc.date.issued2017
dc.date.updated2020-11-02T04:18:35Z
dc.description.abstractBackground: The intensive care unit (ICU) environment exposes patients to noise levels that may result in substantial sleep disruption. There is a need to accurately describe the intensity pattern and source of noise in the ICU in order to develop effective sound abatement strategies. The objectives of this study were to determine nocturnal noise levels and their variability and the related sources of noise within an Australian tertiary ICU. Methods: An observational cross-sectional study was conducted in a 24-bed open-plan ICU. Sound levels were recorded overnight during three nights at 5-s epochs using Extech (SDL 600) sound monitors. Noise sources were concurrently logged by two research assistants. Results: The mean recorded ambient noise level in the ICU was 52.85 decibels (dB) (standard deviation (SD) 5.89), with a maximum noise recording at 98.3 dB (A). All recorded measurements exceeded the WHO recommendations. Noise variability per minute ranged from 9.9 to 44 dB (A), with peak noise levels >70 dB (A) occurring 10 times/hour (SD 11.4). Staff were identified as the most common source accounting for 35% of all noise. Mean noise levels in single-patient rooms compared with open-bed areas were 53.5 vs 53 dB (p = 0.37), respectively. Conclusion: Mean noise levels exceeded those recommended by the WHO resulting in an acoustical intensity of 193 times greater than the recommended and demonstrated a high degree of unpredictable variability, with the primary noise sources coming from staff conversations. The lack of protective effects of single rooms and the contributing effects that staffs have on noise levels are important factors when considering sound abatement strategies.en_AU
dc.description.sponsorshipThis study was funded by the Canberra Hospital Foundation and the Office of the Chief Nurse, Australian Capital Territory Healthen_AU
dc.format.mimetypeapplication/pdfen_AU
dc.identifier.issn2052-0492en_AU
dc.identifier.urihttp://hdl.handle.net/1885/219346
dc.language.isoen_AUen_AU
dc.provenance© The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.en_AU
dc.publisherBioMed Centralen_AU
dc.rights© The Author(s).en_AU
dc.rights.licenseCreative Commons Attribution 4.0 International Licenseen_AU
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en_AU
dc.sourceJournal of Intensive Careen_AU
dc.subjectCritical careen_AU
dc.subjectDisturbanceen_AU
dc.subjectIntensive careen_AU
dc.subjectNoiseen_AU
dc.subjectSleep disturbanceen_AU
dc.subjectStaffen_AU
dc.titleThe nocturnal acoustical intensity of the intensive care environment: An observational studyen_AU
dc.typeJournal articleen_AU
dcterms.accessRightsOpen Accessen_AU
local.bibliographicCitation.issue1en_AU
local.bibliographicCitation.lastpage8en_AU
local.bibliographicCitation.startpage1en_AU
local.contributor.affiliationDelaney, Lori, Non-ANU institution, The Canberra Hospitalen_AU
local.contributor.affiliationCurrie, Marian, College of Health and Medicine, ANUen_AU
local.contributor.affiliationHuang, Carol, College of Health and Medicine, ANUen_AU
local.contributor.affiliationLopez, Violeta, National University of Singaporeen_AU
local.contributor.affiliationLitton, Edward, University of Western Australiaen_AU
local.contributor.affiliationVan Haren, Frank, College of Health and Medicine, ANUen_AU
local.contributor.authoruidDelaney, Lori, u5411234en_AU
local.contributor.authoruidCurrie, Marian, u4003416en_AU
local.contributor.authoruidHuang, Carol, u5673948en_AU
local.contributor.authoruidVan Haren, Frank, u5325459en_AU
local.description.notesImported from ARIESen_AU
local.identifier.absfor110310 - Intensive Careen_AU
local.identifier.absseo920199 - Clinical Health (Organs, Diseases and Abnormal Conditions) not elsewhere classifieden_AU
local.identifier.ariespublicationa383154xPUB7542en_AU
local.identifier.citationvolume5en_AU
local.identifier.doi10.1186/s40560-017-0237-9en_AU
local.identifier.scopusID2-s2.0-85026305435
local.identifier.thomsonID000405110100001
local.publisher.urlhttps://jintensivecare.biomedcentral.com/en_AU
local.type.statusPublished Versionen_AU

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Delaney_The_nocturnal_acoustical_2017.pdf
Size:
943.5 KB
Format:
Adobe Portable Document Format