Utility of a guiding catheter for conduction system pacing: an early multicenter experience

dc.contributor.authorPooter, Jan De
dc.contributor.authorBulava, Alan
dc.contributor.authorGras, Daniel
dc.contributor.authorTimmer, Stefan
dc.contributor.authorChan, Gary Chin-Pang
dc.contributor.authorClementy, Nicolas
dc.contributor.authorPathak, Rajeev
dc.contributor.authorHealy, Stewart
dc.contributor.authorL�sebrink, Ulrich
dc.contributor.authorZanon, Francesco
dc.date.accessioned2024-06-18T00:26:47Z
dc.date.available2024-06-18T00:26:47Z
dc.date.issued2024
dc.date.updated2024-05-19T08:17:54Z
dc.description.abstractBackground Conduction system pacing (CSP), either as His bundle pacing (HBP) or as left bundle branch area pacing (LBBAP), may be superior to right ventricular apical or septal pacing. Objective The study sought to present acute results for a new guiding catheter (Biotronik Selectra 3D) designed for CSP implantations of a retractable screw-in lead (Biotronik Solia S). Methods The primary endpoint of the prospective, international nonrandomized BIO|MASTER.Selectra 3D study was freedom from catheter-related serious adverse device effects (SADEs) within 1 week of lead implantation. Results Of 157 enrolled patients, CSP was achieved in 147 (93.6%) patients. No SADEs occurred within 7 days. LBBAP was achieved in 82 patients (45 as crossover from an HBP attempt) and HBP in 65 (44.2%) patients. In centers considering both HBP and LBBAP, the CSP implantation success approached 99%. Successful CSP implantations lasted on average ∼50 minutes (fluoroscopy ∼6 minutes). Most procedures (87.9%) needed only 1 catheter, even after switch from HBP to LBBAP. The catheter’s handling was rated largely positive. In patients without bundle branch block, mean QRS duration increased from 106 ms (intrinsic) to 122 ms (CSP) (P = .001). In patients with bundle branch block, mean QRS duration decreased from 151 ms (intrinsic) to 137 ms (CSP) (P = .004). Conclusion The Selectra 3D catheter is a valuable tool for HBP and LBBAP implantations of the stylet-supported pacemaker leads. When implanters considered both HBP and LBBAP, the success rate was ∼99%. Flexibility to change between different approaches may be advisable in heterogeneous and challenging areas, such as CSP implantations.
dc.description.sponsorshipThe study was supported by Biotronik SE & Co KG (Woermannkehre 1, D-12359 Berlin, Germany).
dc.format.mimetypeapplication/pdfen_AU
dc.identifier.issn26665018
dc.identifier.urihttps://hdl.handle.net/1885/733713254
dc.language.isoen_AUen_AU
dc.provenanceThis is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
dc.publisherElsevier
dc.rights© 2023 The authors
dc.rights.licenseCreative Commons Attribution licence
dc.rights.urihttp://creativecommons.org/licenses/ by-nc-nd/4.0/
dc.sourceHeart Rhythm O2
dc.subjectCardiac pacing
dc.subjectConduction system pacing
dc.subjectPacing lead implantation;
dc.subjectLeft bundle branch area
dc.subjectHis bundle
dc.subjectGuiding catheter;
dc.subjectCatheter handling characteristics
dc.titleUtility of a guiding catheter for conduction system pacing: an early multicenter experience
dc.typeJournal article
dcterms.accessRightsOpen Access
local.bibliographicCitation.issue1
local.bibliographicCitation.lastpage16
local.bibliographicCitation.startpage8
local.contributor.affiliationPooter, Jan De, Universitair Ziekenhuis Gent
local.contributor.affiliationBulava, Alan, České Budějovice Hospital
local.contributor.affiliationGras, Daniel, ‡Hopital Privé du Confluent
local.contributor.affiliationTimmer, Stefan, Noordwest Ziekenhuisgroep
local.contributor.affiliationChan, Gary Chin-Pang, Prince of Wales Hospital
local.contributor.affiliationClementy, Nicolas, Centre Hospitalier Régional Universitaire de Tours,
local.contributor.affiliationPathak, Rajeev, College of Health and Medicine, ANU
local.contributor.affiliationHealy, Stewart, Monash Medical Centre
local.contributor.affiliationLesebrink, Ulrich, Universitatsklinikum Gießen und Marburg
local.contributor.affiliationZanon, Francesco, Santa Maria della Misericordia
local.contributor.authoruidPathak, Rajeev, u1060627
local.description.notesImported from ARIES
local.identifier.absfor320101 - Cardiology (incl. cardiovascular diseases)
local.identifier.absseo200105 - Treatment of human diseases and conditions
local.identifier.ariespublicationa383154xPUB46326
local.identifier.citationvolume5
local.identifier.doi10.1016/j.hroo.2023.11.017
local.identifier.scopusID2-s2.0-85181683275
local.publisher.urlhttps://www.heartrhythmopen.com/
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PIIS2666501823003082.pdf
Size:
970.29 KB
Format:
Adobe Portable Document Format