All-optical low noise fiber Bragg grating microphone
Loading...
Date
Authors
Bandutunga, Chathura P
Fleddermann, Roland
Gray, Malcolm B
Close, John D
Chow, Jong H
Journal Title
Journal ISSN
Volume Title
Publisher
Optical Society of America
Abstract
We present an all-fiber design for a microphone using a fiber Bragg grating Fabry-Perot resonator attached to a diaphragm transducer. We analytically model and verify the fiber-diaphragm mechanical interaction, using the Hänsch-Couillaud readout technique to provide necessary sensitivity. We achieved a noise-equivalent strain sensitivity of 7.1×10<sup>-12</sup> ϵ/Hz, which corresponds to a sound pressure of 74 μPa/Hz at 1 kHz limited by laser frequency noise and yielding a signal-to-noise ratio of 47±2 dB with a 1 Pa drive at 1 kHz, in close agreement with modeled results.