Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Sensitive high resolution ion microprobe – stable isotope (SHRIMP-SI) analysis of water in silicate glasses and nominally anhydrous reference minerals

Loading...
Thumbnail Image

Date

Authors

Turner, Michael
Ireland, Trevor
Hermann, Joerg
Holden, Peter
Padrón-Navarta, José Alberto
Hauri, Erik H.
Turner, Simon

Journal Title

Journal ISSN

Volume Title

Publisher

Royal Society of Chemistry

Abstract

Low-level water measurements of geological materials are fundamental in understanding the volatile inventories of the Earth from the mantle to crustal reservoirs. Here we describe the development of microanalytical techniques using the new SHRIMP SI ion microprobe to measure the abundances of OH− (as a proxy for water) in volcanic glass and nominally anhydrous minerals (NAMs). Samples were first analysed at the Carnegie Institute of Washington (CIW) on their Cameca ims-6f with calibrations based on previous FTIR and manometry analyses. SHRIMP SI is a large geometry ion microprobe and is currently mainly used for O and S isotope analyses. The analytical protocol used here incorporates multiple collection of 16O− and 16O1H− allowing rapid measurements. A single calibration line incorporating all glasses and NAMs for the SHRIMP SI allows calibration of 16O1H−/16O− to H2O over a wide range in concentration (50 to 15 000 ppm H2O). This calibration line has around a 10% uncertainty, which appears to be limited only by sample heterogeneity. The current background for SHRIMP analysis is between 20–40 ppm but this is expected to improve with improved pumping on the source chamber. A current limitation to water analysis of NAM samples, by any technique, is having a range of standard materials to enable OH− calibration to absolute H2O concentrations. Data are presented for 7 NAM samples (2 olivines, 2 orthopyroxenes and 3 clinopyroxenes) that appear to be promising as potential standards for international laboratory H2O measurements. These NAM samples have been analysed and characterised here by SHRIMP SI, FTIR, EMP and the Cameca ims-6f ion microprobe at CIW. Four of these samples have previously been measured by manometry to determine absolute H2O concentrations.

Description

Keywords

Citation

Source

Journal of Analytical Atomic Spectrometry

Book Title

Entity type

Access Statement

Open Access

License Rights

Restricted until

Downloads

File
Description
Author/s Accepted Manuscript (AAM) / Post-print