Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Silhouette-Based Markerless Motion Estimation of Awake Rodents in PET

Loading...
Thumbnail Image

Date

Authors

Kyme, Andre Z
Strenge, Paul
Lee, Felicity
Meikle, Steven R

Journal Title

Journal ISSN

Volume Title

Publisher

Conference Organising Committee

Abstract

The ability to image the brain of a freely moving rodent using motion-compensated PET presents many exciting possibilities for exploring the links between brain function and behavior. Markerless optical approaches for pose estimation have several potential advantages over marker-based methods: improved accuracy and increased range of detectable motion; no 'decoupling' of marker and head motion; and no acclimatization of the animals to attached markers. Our aim in this work was to describe and validate a silhouette-based multi-camera method for estimating the pose of a rat. Random-walk and K-means clustering approaches were very adaptable to uneven lighting and generally provided excellent object segmentations. In obtaining a high quality rat model, shape-from-silhouette and laser scanning both resulted in useful models; laser scanning provided sub-millimeter resolution with very few artifacts and was the method of choice. In our experimental validation, the 3D-2D (model-silhouette) optimization clearly converged to sub-degree and sub-millimeter alignment of the measured and estimated silhouettes. The average discrepancy between test points transformed using the estimated versus ground-truth poses was 0.94 mm ± 0.51 mm. This investigation focused on rigid motion of a rat phantom as a proof-of-principle of the technique. Future work will focus on investigating the potential of designing a non-rigid rodent body model in order to apply the method to a freely moving animal during PET imaging.

Description

Keywords

Citation

Source

2017 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2017 - Conference Proceedings

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31