Comparison of Ribbon Light Management Designs for Photovoltaic Modules
| dc.contributor.author | Li, Yang | |
| dc.contributor.author | Song, Ning | |
| dc.contributor.author | Hsiao, Pei-Chieh | |
| dc.contributor.author | Mungra, Mreedula | |
| dc.contributor.author | Ouyang, Z | |
| dc.contributor.author | Haedrich, Ingrid | |
| dc.contributor.author | Ernst, Marco | |
| dc.contributor.author | Newman, Bonna | |
| dc.contributor.author | Jansen, Mark | |
| dc.contributor.author | Zhu, Chen | |
| dc.contributor.author | Lv, Jun | |
| dc.contributor.author | Zhang, Xueqing | |
| dc.contributor.author | Lennon, Alison | |
| dc.coverage.spatial | Chicago, IL, USA | |
| dc.date.accessioned | 2024-01-17T03:49:37Z | |
| dc.date.created | June 16-21 2019 | |
| dc.date.issued | 2020 | |
| dc.date.updated | 2022-10-02T07:16:41Z | |
| dc.description.abstract | New ribbon designs to minimize shading losses are evaluated and compared. With a simulation methodology considering interaction of optics from cells, modules and systems in realistic conditions, the angular responses of modules and annual yield enhancements with these designs are estimated. It is shown that the annual yield cannot be easily estimated from STC measurements and an incident angle multiplier coefficient is proposed for correction. | en_AU |
| dc.description.sponsorship | The authors acknowledge support from the Australian Government through the Australian Renewable Energy Agency (ARENA) in their funding of ARENA grant 2017/RND002. | en_AU |
| dc.format.mimetype | application/pdf | en_AU |
| dc.identifier.isbn | 978-1-7281-0494-2 | en_AU |
| dc.identifier.uri | http://hdl.handle.net/1885/311559 | |
| dc.language.iso | en_AU | en_AU |
| dc.publisher | IEEE | en_AU |
| dc.relation.ispartofseries | 46th IEEE Photovoltaic Specialists Conference, PVSC 2019 | en_AU |
| dc.rights | © 2019 IEEE | en_AU |
| dc.source | Unravelling Optical and Electrical Degradation of Perovskite Solar Cells and Impact on Perovskite/Silicon Monolithic Tandem Modules | en_AU |
| dc.subject | photovoltaic systems | en_AU |
| dc.subject | solar panels | en_AU |
| dc.subject | light trapping | en_AU |
| dc.title | Comparison of Ribbon Light Management Designs for Photovoltaic Modules | en_AU |
| dc.type | Conference paper | en_AU |
| local.bibliographicCitation.lastpage | 2222 | en_AU |
| local.bibliographicCitation.startpage | 2219 | en_AU |
| local.contributor.affiliation | Li, Yang, University of New South Wales | en_AU |
| local.contributor.affiliation | Song, Ning, UNSW | en_AU |
| local.contributor.affiliation | Hsiao, Pei-Chieh, University of New South Wales | en_AU |
| local.contributor.affiliation | Mungra, Mreedula, UNSW Sydney | en_AU |
| local.contributor.affiliation | Ouyang, Z, University of New South Wales | en_AU |
| local.contributor.affiliation | Haedrich, Ingrid, College of Engineering and Computer Science, ANU | en_AU |
| local.contributor.affiliation | Ernst, Marco, College of Engineering and Computer Science, ANU | en_AU |
| local.contributor.affiliation | Newman, Bonna, ECN part of TNO | en_AU |
| local.contributor.affiliation | Jansen, Mark, ECN part of TNO | en_AU |
| local.contributor.affiliation | Zhu, Chen, LONGi Solar Technology Co., Ltd. | en_AU |
| local.contributor.affiliation | Lv, Jun, LONGi Solar Technology Co., Ltd. | en_AU |
| local.contributor.affiliation | Zhang, Xueqing, Hebei Sizhuo Photovoltaic Technology Co., Ltd. | en_AU |
| local.contributor.affiliation | Lennon, Alison, University of New South Wales | en_AU |
| local.contributor.authoruid | Haedrich, Ingrid, u5712688 | en_AU |
| local.contributor.authoruid | Ernst, Marco, u5457130 | en_AU |
| local.description.embargo | 2099-12-31 | |
| local.description.notes | Imported from ARIES | en_AU |
| local.identifier.absfor | 400800 - Electrical engineering | en_AU |
| local.identifier.ariespublication | a383154xPUB11719 | en_AU |
| local.identifier.doi | 10.1109/PVSC40753.2019.8980792 | en_AU |
| local.identifier.scopusID | 2-s2.0-85081622232 | |
| local.publisher.url | https://ieeexplore.ieee.org/ | en_AU |
| local.type.status | Published Version | en_AU |
Downloads
Original bundle
1 - 1 of 1
Loading...
- Name:
- Comparison_of_Ribbon_Light_Management_Designs_for_Photovoltaic_Modules.pdf
- Size:
- 2.56 MB
- Format:
- Adobe Portable Document Format
- Description: