Investigation of Microstructural Features in Regenerating Bone using Micro Computed Tomography
| dc.contributor.author | Jones, Anthony | |
| dc.contributor.author | Sakellariou, Arthur | |
| dc.contributor.author | Limaye, Ajay | |
| dc.contributor.author | Arns, Christoph | |
| dc.contributor.author | Senden, Timothy | |
| dc.contributor.author | Sawkins, Tim | |
| dc.contributor.author | Knackstedt, Mark | |
| dc.contributor.author | Rohner, Dennis | |
| dc.contributor.author | Hutmacher, Dietmar W | |
| dc.contributor.author | Brandwood, Arthur | |
| dc.contributor.author | Milthorpe, Bruce | |
| dc.date.accessioned | 2015-12-13T22:39:27Z | |
| dc.date.issued | 2004 | |
| dc.date.updated | 2015-12-11T09:49:47Z | |
| dc.description.abstract | We illustrate some of the uses of micro-computed tomography (micro-CT) to study tissue-engineered bone using a micro-CT facility for imaging and visualizing biomaterials in three dimensions (3-D). The micro-CT is capable of acquiring 3D X-ray CT images made up of 20003 voxels on specimens up to 5 cm in extent with resolutions down to 2 μm. This allows the 3-D structure of tissue-engineered materials to be imaged across orders of magnitude in resolution. This capability is used to examine an explanted, tissue-engineered bone material based on a polycaprolactone scaffold and autologous bone marrow cells. Imaging of the tissue-engineered bone at a scale of 1 cm and resolutions of 10 μm allows one to visualize the complex ingrowth of bone into the polymer scaffold. From a theoretical viewpoint the voxel data may also be used to calculate expected mechanical properties of the tissue-engineered implant. These observations illustrate the benefits of tomography over traditional techniques for the characterization of bone morphology and interconnectivity. As the method is nondestructive it can perform a complimentary role to current histomorphometric techniques. | |
| dc.identifier.issn | 0957-4530 | |
| dc.identifier.uri | http://hdl.handle.net/1885/77792 | |
| dc.publisher | Kluwer Academic Publishers | |
| dc.source | Journal of Materials Science - Materials in Medicine | |
| dc.subject | Keywords: Computerized tomography; Medical imaging; Microstructure; Nondestructive examination; X rays; Micro-computed tomography (micro-CT); Tissue engineering; Bone; biomaterial; polycaprolactone; polymer; animal experiment; biomechanics; bone growth; bone marrow | |
| dc.title | Investigation of Microstructural Features in Regenerating Bone using Micro Computed Tomography | |
| dc.type | Journal article | |
| local.bibliographicCitation.lastpage | 532 | |
| local.bibliographicCitation.startpage | 529 | |
| local.contributor.affiliation | Jones, Anthony, College of Physical and Mathematical Sciences, ANU | |
| local.contributor.affiliation | Sakellariou, Arthur, College of Physical and Mathematical Sciences, ANU | |
| local.contributor.affiliation | Limaye, Ajay, College of Physical and Mathematical Sciences, ANU | |
| local.contributor.affiliation | Arns, Christoph, College of Physical and Mathematical Sciences, ANU | |
| local.contributor.affiliation | Senden, Timothy , College of Physical and Mathematical Sciences, ANU | |
| local.contributor.affiliation | Sawkins, Tim, College of Physical and Mathematical Sciences, ANU | |
| local.contributor.affiliation | Knackstedt, Mark, College of Physical and Mathematical Sciences, ANU | |
| local.contributor.affiliation | Rohner, Dennis, Cranio-Facial-Center (cfc) Hirslanden | |
| local.contributor.affiliation | Hutmacher, Dietmar W, National University of Singapore | |
| local.contributor.affiliation | Brandwood, Arthur, University of New South Wales | |
| local.contributor.affiliation | Milthorpe, Bruce, University of New South Wales | |
| local.contributor.authoruid | Jones, Anthony, u3096904 | |
| local.contributor.authoruid | Sakellariou, Arthur, u4010587 | |
| local.contributor.authoruid | Limaye, Ajay, u9707062 | |
| local.contributor.authoruid | Arns, Christoph, u4044259 | |
| local.contributor.authoruid | Senden, Timothy , u8612475 | |
| local.contributor.authoruid | Sawkins, Tim, u8300523 | |
| local.contributor.authoruid | Knackstedt, Mark, u4031845 | |
| local.description.embargo | 2037-12-31 | |
| local.description.notes | Imported from ARIES | |
| local.description.refereed | Yes | |
| local.identifier.absfor | 029903 - Medical Physics | |
| local.identifier.ariespublication | MigratedxPub6572 | |
| local.identifier.citationvolume | 15 | |
| local.identifier.doi | 10.1023/B:JMSM.0000021133.48661.62 | |
| local.identifier.scopusID | 2-s2.0-3543034606 | |
| local.type.status | Published Version |
Downloads
Original bundle
1 - 1 of 1
Loading...
- Name:
- 01_Jones_Investigation_of_2004.pdf
- Size:
- 164.09 KB
- Format:
- Adobe Portable Document Format