Improving spatial-resolution in high cone-angle micro-CT by source deblurring

dc.contributor.authorLi, Heyang (Thomas)
dc.contributor.authorKingston, Andrew
dc.contributor.authorMyers, Glenn
dc.contributor.authorRecur, Benoit
dc.contributor.authorTurner, Michael
dc.contributor.authorSheppard, Adrian
dc.coverage.spatialSan Diego, CA
dc.date.accessioned2015-12-10T23:18:27Z
dc.date.createdAugust 18-20 2014
dc.date.issued2014
dc.date.updated2015-12-10T10:06:38Z
dc.description.abstractMicro scale computed tomography (CT) can resolve many features in cellular structures, bone formations, minerals properties and composite materials not seen at lower spatial-resolution. Those features enable us to build a more comprehensive model for the
dc.identifier.isbn9781628412390
dc.identifier.urihttp://hdl.handle.net/1885/65629
dc.publisherSPIE - The International Society for Optical Engineering
dc.relation.ispartofseriesDevelopments in X-Ray Tomography IX
dc.sourceProceedings of SPIE - The International Society for Optical Engineering
dc.titleImproving spatial-resolution in high cone-angle micro-CT by source deblurring
dc.typeConference paper
local.bibliographicCitation.lastpage11
local.bibliographicCitation.startpage1
local.contributor.affiliationLi, Heyang (Thomas), College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationKingston, Andrew, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationMyers, Glenn, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationRecur, Benoit, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationTurner, Michael, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationSheppard, Adrian, College of Physical and Mathematical Sciences, ANU
local.contributor.authoremailu4684003@anu.edu.au
local.contributor.authoruidLi, Heyang (Thomas), u4684003
local.contributor.authoruidKingston, Andrew, u4438507
local.contributor.authoruidMyers, Glenn, u4703841
local.contributor.authoruidRecur, Benoit, u5450832
local.contributor.authoruidTurner, Michael, u3351931
local.contributor.authoruidSheppard, Adrian, u9204025
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.description.refereedYes
local.identifier.absfor029904 - Synchrotrons; Accelerators; Instruments and Techniques
local.identifier.absfor020402 - Condensed Matter Imaging
local.identifier.absfor080106 - Image Processing
local.identifier.ariespublicationa383154xPUB1135
local.identifier.doi10.1117/12.2062415
local.identifier.scopusID2-s2.0-84923028610
local.identifier.thomsonID000344554400010
local.identifier.uidSubmittedBya383154
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
01_Li_Improving_spatial-resolution_2014.pdf
Size:
1.08 MB
Format:
Adobe Portable Document Format
Back to topicon-arrow-up-solid
 
APRU
IARU
 
edX
Group of Eight Member

Acknowledgement of Country

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.


Contact ANUCopyrightDisclaimerPrivacyFreedom of Information

+61 2 6125 5111 The Australian National University, Canberra

TEQSA Provider ID: PRV12002 (Australian University) CRICOS Provider Code: 00120C ABN: 52 234 063 906