Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

The influence of sampling errors on test-retest variability in perimetry

Loading...
Thumbnail Image

Date

Authors

Maddess, Ted

Journal Title

Journal ISSN

Volume Title

Publisher

Association for Research in Vision and Opthalmology

Abstract

PURPOSE. To determine whether visual fields measured by standard automated perimetry (SAP) can be distorted by higherspatial-frequency image components and, in particular, whether test-retest variability of SAP fields can be explained by the combination of small scale fixational drift, small stimulus size, and coarse spatial sampling of the visual fields. METHODS. Standard SAP test patterns have points 6° apart. The amplitude spectra of the perimeter's 10-2 fields (model 511 Humphrey Field Analyser [HFA]; Carl Zeiss Meditec, Inc., North Ryde, NSW, Australia) were assessed to see whether their finer grained sampling revealed spatial frequencies that could cause distortions of standard fields because of undersampling. Model visual fields were then constructed whose spectra were similar to the 10-2 fields, and test-retest variability was examined for Goldmann sizes III to VI stimuli and Gaussian fixational drift with standard deviations of 0.075° to 0.3°. RESULTS. The 10-2 fields showed significant spatial frequency content up to 0.25 cyc/deg, three times the highest frequency that a 30-2 or 24-2 sample grid can resolve. As reported for SAP, test-retest variability increased with scotoma depth, and increasing the stimulus size from III to VI caused a reduction in test-retest variability, as did reduced fixation jitter. CONCLUSIONS. With fixation drift half the size of that exhibited by good fixators, many of the features of SAP test-retest variability were reproduced. Reducing test-retest variability may therefore involve using large test stimuli that are blurry in appearance and that overlap somewhat when placed on the perimetric test grid. Overlap across the meridians should perhaps be avoided.

Description

Citation

Source

Investigative Ophthalmology and Visual Science

Book Title

Entity type

Access Statement

Open Access

License Rights

Restricted until