Open Research will be updating the system on Tuesday, 14 July 2026, from 8:15 to 9:00 AM. We apologise for any inconvenience caused.

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Controls on entrainment of a dense chemical layer by thermal plumes

Loading...
Thumbnail Image

Date

Authors

Huang, Jinshui

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

Results from two-dimensional axisymmetric numerical models of a chemically dense layer entrained by thermal plumes, featuring a plume temperature structure fixed a priori as a Gaussian function and strongly temperature-dependent viscosity, show that the entrainment rate, Q, is controlled by the radius of the thermal plume, rT, the ratio of excess chemical to thermal buoyancy, Rb, and viscosity contrast across the two layers, γ. Fitting of the numerical results shows that Q ∼ γ0.65 rT3.90 Rb- 2.89 γ0.17. A smaller rT and/or a larger Rb results in a smaller entrainment rate, as expected. However, the dependence of Q on Rb is much stronger than previously suggested if the fluid viscosity is strongly temperature dependent. The effects of γ on Q depend on Rb because the scale of Q on Rb is dependent on γ, and when Rb is around 1.8, the dependence of Q on γ is weak. The results also show that the dependences of the radius, rc, and the vertical velocity, Vzc, of the chemical plume on Rb are also much stronger than previously suggested if the fluid viscosity is strongly temperature dependent. Scaling the numerical results to the Earth's mantle suggests that the chemically dense layer in the mantle may survive through the age of the Earth with insignificant entrainment, e.g. in a mantle with a reference viscosity of 5 × 1021 Pa s and a reference density of 4000 kg/m3, a thermal plume that has a radius of 80 km, a temperature of 600 K hotter and a viscosity of 100 times lower at the center of the plume than in the ambient mantle can only entrain less than 5% of the bottom chemical layer that is 300 km thick, 0.9% denser than the above mantle (Rb = 1.5) and spread over an area of size ∼0.5D2 (D = 2900 km, thickness of the mantle) through the age of the Earth.

Description

Citation

Source

Physics of the Earth and Planetary Interiors

Book Title

Entity type

Access Statement

License Rights

Restricted until

abcd