Referencing Laser Frequency to Ultra-stable Reference Clocks for Future MCM Missions

dc.contributor.authorWade, Andrew
dc.contributor.authorRees, Emily Rose
dc.contributor.authorShaddock, Daniel
dc.contributor.authorMcKenzie, Kirk
dc.coverage.spatialSan Jose, CA, USA
dc.date.accessioned2023-07-14T06:16:03Z
dc.date.created9-14 May 2021
dc.date.issued2021
dc.date.updated2022-05-08T08:16:58Z
dc.description.abstractWe present an electro-optic technique that generates an independent readout of optical cavity mode frequency spacing. We demonstrate a fractional frequency drift resolution of 1 ppb, sufficient to meet expected future mass change mission requirements.en_AU
dc.format.mimetypeapplication/pdfen_AU
dc.identifier.isbn978-1-943580-91-0en_AU
dc.identifier.urihttp://hdl.handle.net/1885/294241
dc.language.isoen_AUen_AU
dc.publisherOptica Publishing Groupen_AU
dc.relation.ispartofseries2021 Conference on Lasers and Electro-Optics (CLEO)en_AU
dc.rights© 2021 OSAen_AU
dc.source2021 Conference on Lasers and Electro-Optics (CLEO)en_AU
dc.titleReferencing Laser Frequency to Ultra-stable Reference Clocks for Future MCM Missionsen_AU
dc.typeConference paperen_AU
local.bibliographicCitation.lastpage2en_AU
local.bibliographicCitation.startpage1en_AU
local.contributor.affiliationWade, Andrew, College of Science, ANUen_AU
local.contributor.affiliationRees, Emily Rose, College of Science, ANUen_AU
local.contributor.affiliationShaddock, Daniel, College of Science, ANUen_AU
local.contributor.affiliationMcKenzie, Kirk, College of Science, ANUen_AU
local.contributor.authoruidWade, Andrew, u4311433en_AU
local.contributor.authoruidRees, Emily Rose, u5812108en_AU
local.contributor.authoruidShaddock, Daniel, u9701638en_AU
local.contributor.authoruidMcKenzie, Kirk, u4017303en_AU
local.description.embargo2099-12-31
local.description.notesImported from ARIESen_AU
local.description.refereedYes
local.identifier.absfor510200 - Atomic, molecular and optical physicsen_AU
local.identifier.absseo280120 - Expanding knowledge in the physical sciencesen_AU
local.identifier.ariespublicationa383154xPUB24201en_AU
local.identifier.doi10.1364/CLEO_SI.2021.STh1C.2en_AU
local.identifier.scopusID2-s2.0-85120477896
local.publisher.urlhttps://opg.optica.org/en_AU
local.type.statusPublished Versionen_AU

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Referencing Laser Frequency To Ultra-stable Reference.pdf
Size:
833.02 KB
Format:
Adobe Portable Document Format
Description: