Thirty-minute compared to standardised office blood pressure measurement in general practice

Date

2011

Authors

Scherpbier-de Haan, Nynke D
Van der Wel, Mark
Schoenmakers, G
Boudewijns, S
Peer, PGM
Thien, Theo
Bakx, JC
van Weel, Chris

Journal Title

Journal ISSN

Volume Title

Publisher

Royal College of General Practitioners

Abstract

Background: Although blood pressure measurement is one of themost frequently performed measurements in clinical practice, there are concerns about its reliability. Serial, automated oscillometric blood pressure measurement has the potential to reduce measurement bias and 'white-coat effect'. Aim: To study agreement of 30-minute office blood pressure measurement (OBPM) with standardised OBPM, and to compare repeatability. Design and setting: Method comparison study in two general practices in the Netherlands. Method: Thirty-minute and standardised OBPM was carried out with the same, validated device in 83 adult patients, and the procedure was repeated after 2 weeks. During 30-minute OBPM, blood pressure was measured automatically every 3minutes, with the patient in a sitting position, alone in a quiet room. Agreement between 30-minute and standardised OBPM was assessed by Bland-Altman analysis. Repeatability of the blood pressure measurement methods after 2 weeks was expressed as the mean difference in combination with the standard deviation of difference (SDD). Results: Mean 30-minute OBPM readings were 7.6/2.5 mmHg (95% confidence interval [CI] = 6.1 to 9.1/1.5 to 3.4 mmHg) lower than standardised OBPM readings. The mean difference and SDD between repeated 30-minute OBPMs (mean difference = 3/1 mmHg, 95%CI = 1 to 5/0 to 2 mmHg; SDD 9.5/5.3 mmHg) were lower than those of standardised OBPMs (mean difference = 6/2 mmHg, 95%CI = 4 to 8/1 to 4 mmHg; SDD 10.9/6.3 mmHg). Conclusion: Thirty-minute OBPM resulted in lower readings than standardised OBPM and had a better repeatability. These results suggest that 30-minute OBPM better reflects the patient's true blood pressure than standardised OBPM does.

Description

Keywords

Keywords: adult; ambulatory care; article; blood pressure measurement; clinical trial; comparative study; controlled study; female; general practice; human; major clinical study; male; repeat procedure; sitting; Blood Pressure Determination; Female; General Practic Blood pressure; General practice; Reproducibility of results

Citation

Source

British Journal of General Practice

Type

Journal article

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31