Modified inverted selective plane illumination microscopy for sub-micrometer imaging resolution in polydimethylsiloxane soft lithography devices
Loading...
Date
Authors
Xu, Tienan
Lim, Daniel
Zheng, Yujie
Jung, MoonSun
Gaus, Katharina
Gardiner, Elizabeth
Lee, W M Steve
Journal Title
Journal ISSN
Volume Title
Publisher
Royal Society of Chemistry
Abstract
Moldable, transparent polydimethylsiloxane (PDMS) elastomer microdevices enable a broad range of
complex studies of three-dimensional cellular networks in their microenvironment in vitro. However, the
uneven distribution of refractive index change, external to PDMS devices and internally in the sample
chamber, creates a significant optical path difference (OPD) that distorts the light sheet beam and so
restricts diffraction limited performance. We experimentally showed that an OPD of 120 μm results in the
broadening of the lateral point spread function by over 4-fold. In this paper, we demonstrate steps to adapt
a commercial inverted selective plane illumination microscope (iSPIM) and remove the OPD so as to
achieve sub-micrometer imaging ranging from 0.6 ± 0.04 μm to 0.91 ± 0.03 μm of a fluorescence
biological sample suspended in regular saline (RI ≈1.34) enclosed in 1.2 to 2 mm thick micromolded PDMS
microdevices. We have proven that the removal of the OPD from the external PDMS layer by refractive
index (RI) matching with a readily accessible, inexpensive sucrose solution is critical to achieve a >3-fold
imaging resolution improvement. To monitor the RI matching process, a single-mode fiber (SMF)
illuminator was integrated into the iSPIM. To remove the OPD inside the PDMS channel, we used an
electrically tunable lens (ETL) that par-focuses the light sheet beam with the detection objective lens and
so minimised axial distortions to attain sub-micrometer imaging resolution. We termed this new light sheet
imaging protocol as modified inverted selective plane illumination microscopy (m-iSPIM). Using the high
spatial–temporal 3D imaging of m-iSPIM, we experimentally captured single platelet (≈2 μm) recruitment
to a platelet aggregate (22.5 μm × 22.5 μm × 6 μm) under flow at a 150 μm depth within a microfluidic
channel. m-iSPIM paves the way for the application of light sheet imaging to a wide range of 3D biological
models in microfluidic devices which recapitulate features of the physiological microenvironment and
elucidate subcellular responses.