Dielectric Self-energy in Poisson-Boltzmann and Poisson-Nernst-Planck Models of Ion Channels

dc.contributor.authorCorry, Ben
dc.contributor.authorKuyucak, Serdar
dc.date.accessioned2015-12-13T23:09:49Z
dc.date.issued2003
dc.date.updated2015-12-12T08:20:51Z
dc.description.abstractWe demonstrated previously that the two continuum theories widely used in modeling biological ion channels give unreliable results when the radius of the conduit Is less than two Debye lengths. The reason for this failure is the neglect of surface charges on the protein wall induced by permeating ions. Here we attempt to improve the accuracy of the Poisson-Boltzmann and Polsson-Nernst-Planck theories, when applied to channel-like environments, by including a specific dielectric self-energy term to overcome spurious shielding effects inherent in these theories. By comparing results with Brownian dynamics simulations, we show that the inclusion of an additional term in the equations yields significant qualitative improvements. The modified theories perform well in very wide and very narrow channels, but are less successful at intermediate sizes. The situation is worse In multi-ion channels because of the inability of the continuum theories to handle the ion-to-ion interactions correctly. Thus, further work is required if these continuum theories are to be reliably salvaged for quantitative studies of biological ion channels in all situations.
dc.identifier.issn0006-3495
dc.identifier.urihttp://hdl.handle.net/1885/87174
dc.publisherBiophysical Society
dc.sourceBiophysical Journal
dc.subjectKeywords: ion channel; accuracy; article; dielectric constant; dynamics; energy; model; molecular interaction; simulation; theory; Calcium; Calcium Channels, L-Type; Computer Simulation; Diffusion; Electric Conductivity; Electrochemistry; Energy Transfer; Ion Chann
dc.titleDielectric Self-energy in Poisson-Boltzmann and Poisson-Nernst-Planck Models of Ion Channels
dc.typeJournal article
local.bibliographicCitation.lastpage3606
local.bibliographicCitation.startpage3594
local.contributor.affiliationCorry, Ben, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationKuyucak, Serdar, College of Physical and Mathematical Sciences, ANU
local.contributor.authoruidCorry, Ben, u9719358
local.contributor.authoruidKuyucak, Serdar, u9200181
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.description.refereedYes
local.identifier.absfor029901 - Biological Physics
local.identifier.ariespublicationMigratedxPub16346
local.identifier.citationvolume84
local.identifier.scopusID2-s2.0-0038101633
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Corry_Dielectric_Self-energy_in_2003.pdf
Size:
252.27 KB
Format:
Adobe Portable Document Format