Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

An Experimentally Verified LC-MS Protocol toward an Economical, Reliable, and Quantitative Isotopic Analysis in Nitrogen Reduction Reactions

Loading...
Thumbnail Image

Date

Authors

Saji, Sandra
Lu, Haijiao
Lu, Ziyang
Carroll, Adam
Yin, Zongyou

Journal Title

Journal ISSN

Volume Title

Publisher

Wiley

Abstract

To substitute the energy-intensive Haber-Bosch process for the synthesis of ammonia, some labile techniques, such as photocatalysis, electrocatalysis, photoelectrocatalysis, and photothermocatalysis, have emerged and attracted intense research interest. However, the contamination of the reaction system is one of the major concerns on how to reliably and accurately evaluate the performance of these catalysts, which is why various control studies are involved. Isotopic labeling studies are one of the most reliable control strategies in nitrogen fixation experiments, to ensure that N2 is exclusively the source of the generated ammonia. As a convenient, sensitive and accurate technique distinguished with a quantitative atomic mass resolution, liquid chromatography-mass spectrometry (LC-MS) has been extensively employed for the detection of ammonia in aqueous electrolyte systems. However, the previous work protocols for 15N2 isotopic analysis using LC-MS either involved hazardous procedures which could potentially damage the instrument, or lacked in their experimental verification using real samples. Herein, a safe, reproducible and economical protocol for the detection of ammonia using LC-MS is presented, exhibiting an exponentially steep progressive detectivity of 15N abundance, well verified with a series of experimental results for nitrogen reduction reactions. This is expected to provide a prudent cost-effective and sustainable gateway into isotopic analysis.

Description

Keywords

Citation

Source

Small Methods

Book Title

Entity type

Access Statement

License Rights

Restricted until

2099-12-31