Micro-CT scan with virtual dissection of left ventricle is a non-destructive, reproducible alternative to dissection and weighing for left ventricular size
| dc.contributor.author | Doost, Ata | |
| dc.contributor.author | Rangel, Alejandra | |
| dc.contributor.author | Nguyen, Quang | |
| dc.contributor.author | Morahan, Grant | |
| dc.contributor.author | Arnolda, Leonard | |
| dc.date.accessioned | 2023-10-23T04:25:00Z | |
| dc.date.available | 2023-10-23T04:25:00Z | |
| dc.date.issued | 2020 | |
| dc.date.updated | 2022-08-21T08:16:20Z | |
| dc.description.abstract | Micro-CT scan images enhanced by iodine staining provide high-resolution visualisation of soft tissues in laboratory mice. We have compared Micro-CT scan-derived left ventricular (LV) mass with dissection and weighing. Ex-vivo micro-CT scan images of the mouse hearts were obtained following staining by iodine. The LV was segmented and its volume was assessed using a semi-automated method by Drishti software. The left ventricle was then dissected in the laboratory and its actual weight was measured and compared against the estimated results. LV mass was calculated multiplying its estimated volume and myocardial specific gravity. Thirty-five iodine-stained post-natal mouse hearts were studied. Mice were of either sex and 68 to 352 days old (median age 202 days with interquartile range 103 to 245 days) at the time of sacrifice. Samples were from 20 genetically diverse strains. Median mouse body weight was 29 g with interquartile range 24 to 34 g. Left Ventricular weights ranged from 40.0 to 116.7 mg. The segmented LV mass estimated from micro-CT scan and directly measured dissected LV mass were strongly correlated (R2 = 0. 97). Segmented LV mass derived from Micro-CT images was very similar to the physically dissected LV mass (mean difference = 0.09 mg; 95% confidence interval − 3.29 mg to 3.1 mg). Micro-CT scanning provides a non-destructive, efficient and accurate visualisation tool for anatomical analysis of animal heart models of human cardiovascular conditions. Iodine-stained soft tissue imaging empowers researchers to perform qualitative and quantitative assessment of the cardiac structures with preservation of the samples for future histological analysis. | en_AU |
| dc.format.mimetype | application/pdf | en_AU |
| dc.identifier.issn | 2045-2322 | en_AU |
| dc.identifier.uri | http://hdl.handle.net/1885/303470 | |
| dc.language.iso | en_AU | en_AU |
| dc.provenance | This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. | en_AU |
| dc.publisher | Nature Publishing Group | en_AU |
| dc.rights | © 2020 The authors | en_AU |
| dc.rights.license | Creative Commons Attribution licence | en_AU |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | en_AU |
| dc.source | Scientific Reports | en_AU |
| dc.title | Micro-CT scan with virtual dissection of left ventricle is a non-destructive, reproducible alternative to dissection and weighing for left ventricular size | en_AU |
| dc.type | Journal article | en_AU |
| dcterms.accessRights | Open Access | en_AU |
| local.bibliographicCitation.lastpage | 9 | en_AU |
| local.bibliographicCitation.startpage | 1 | en_AU |
| local.contributor.affiliation | Doost, Ata, College of Health and Medicine, ANU | en_AU |
| local.contributor.affiliation | Rangel, Alejandra, University of Wollongong | en_AU |
| local.contributor.affiliation | Nguyen, Quang, University of Western Australia | en_AU |
| local.contributor.affiliation | Morahan, Grant, University of Western Australia | en_AU |
| local.contributor.affiliation | Arnolda, Leonard, College of Health and Medicine, ANU | en_AU |
| local.contributor.authoruid | Doost, Ata, u6004586 | en_AU |
| local.contributor.authoruid | Arnolda, Leonard, u4719326 | en_AU |
| local.description.notes | Imported from ARIES | en_AU |
| local.identifier.absfor | 320101 - Cardiology (incl. cardiovascular diseases) | en_AU |
| local.identifier.absfor | 320222 - Radiology and organ imaging | en_AU |
| local.identifier.ariespublication | a383154xPUB15267 | en_AU |
| local.identifier.citationvolume | 10 | en_AU |
| local.identifier.doi | 10.1038/s41598-020-70734-3 | en_AU |
| local.identifier.scopusID | 2-s2.0-85089550403 | |
| local.identifier.thomsonID | WOS:000563538400003 | |
| local.publisher.url | https://www.nature.com/ | en_AU |
| local.type.status | Published Version | en_AU |
Downloads
Original bundle
1 - 1 of 1
Loading...
- Name:
- s41598-020-70734-3.pdf
- Size:
- 1.25 MB
- Format:
- Adobe Portable Document Format
- Description: