Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

In situ electrochemical-NMR spectroscopy. Reduction of aromatic halides

Loading...
Thumbnail Image

Date

Authors

Webster, Richard

Journal Title

Journal ISSN

Volume Title

Publisher

American Chemical Society

Abstract

A three-electrode, two-compartment cylindrical electrochemical cell has been constructed for in situ operation in a 500 MHz 1H NMR spectrometer. The cell was designed around a standard 10-mm sample tube holder and is lowered into position within the magnet by height-adjustable aluminum rods that support the wires connecting the potentiostat to the working, auxiliary and reference electrodes. The electrochemical cell functions under diffusion-controlled conditions in nonspinning mode and is able to operate under variable temperature and oxygen-free regimes. The working electrode consists of a 10-nm-thick gold film deposited onto the surface of a 7.49-mm-o.d. glass NMR tube that is located directly within the radio frequency coils of the NMR probe. The NMR spectra were collected simultaneously to the current flowing during the electrolysis with typical NMR line widths being approximately 2 Hz. The highly symmetrical nature of the cell design meant that probe tuning and gradient shimming changed minimally between experiments, which allowed standard shim sets to be saved and recalled for later use, thereby greatly reducing the time taken for tuning processes. Insertion and removal of the cell from within the magnet is achieved within a few seconds, which combined with the rapid shimming process makes the cell suitable for routine operation. The cell was used to study the in situ reduction of 9-bromoanthracene, 9-chloroanthracene, and 4-bromobenzophenone in deuterated acetonitrile with tetrabutylammonium hexafluorophosphate as the supporting electrolyte.

Description

Citation

Source

Analytical Chemistry

Book Title

Entity type

Access Statement

License Rights

Restricted until

abcd