Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

An auto-focus method for generating sharp 3D tomographic images

dc.contributor.authorKingston, Andrew
dc.contributor.authorSakellariou, Arthur
dc.contributor.authorSheppard, Adrian
dc.contributor.authorVarslot, Trond
dc.contributor.authorLatham, Shane
dc.date.accessioned2015-12-10T22:51:40Z
dc.date.issued2010
dc.date.updated2016-02-24T11:56:03Z
dc.description.abstractWe present a simple, robust, and versatile solution to the problem of blurred tomographic images as a result of imperfect geometric hardware alignment. The necessary precision for the alignment between the various components of a tomographic instrument is in many cases technologically difficult to implement, or requires impractical stability. Misaligned projection sets are not self-consistent and give blurred tomographic reconstructions. We have developed an off-line software method that utilises a geometric model to parameterise the alignment, and an algorithm for determining the alignment parameter set that gives the sharpest tomogram. It is an adaptation of passive auto-focus methods that have been used to obtain sharp images in optical instruments for decades. To minimise computation time, the auto-focus strategy is a multi-scale iterative technique implemented on a selection of 2D cross-sections of the tomogram. For each cross-section, the sharpness is evaluated while scanning over various combinations of alignment parameters. The parameter set that maximises sharpness is used to reconstruct the 3D tomogram. To apply the corrections, the projection data are re-mapped, or the reconstruction algorithm is modified. The entire alignment process takes less time than that of a full-scale 3D reconstruction. It can in principle be applied to any cone or parallel beam CT with circular, helical, or more general trajectories. It can also be applied retrospectively to archived projection data without any additional information. This concept is fully tested and implemented for routine use in the ANU micro-CT reconstruction software suite and has made the entire reconstruction pipeline robust and autonomous.
dc.identifier.issn1605-7422
dc.identifier.urihttp://hdl.handle.net/1885/59145
dc.publisherSPIE - The International Society for Optical Engineering
dc.sourceProceedings of SPIE - Progress in Biomedical Optics and Imaging
dc.subjectKeywords: 3D reconstruction; Alignment parameter; Auto-focus; Computation time; Computed Tomography; Geometric models; Iterative technique; Micro CT; Multiscales; Off-line softwares; Parallel beams; Parameter set; Projection data; Projection sets; Reconstruction al alignment; autofocus; Computed tomography; sharpness
dc.titleAn auto-focus method for generating sharp 3D tomographic images
dc.typeJournal article
local.bibliographicCitation.startpageArticle number 78040J
local.contributor.affiliationKingston, Andrew, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationSakellariou, Arthur, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationSheppard, Adrian, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationVarslot, Trond, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationLatham, Shane, College of Physical and Mathematical Sciences, ANU
local.contributor.authoruidKingston, Andrew, u4438507
local.contributor.authoruidSakellariou, Arthur, u4010587
local.contributor.authoruidSheppard, Adrian, u9204025
local.contributor.authoruidVarslot, Trond, u3082880
local.contributor.authoruidLatham, Shane, u3813363
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor020402 - Condensed Matter Imaging
local.identifier.absfor080106 - Image Processing
local.identifier.absfor029904 - Synchrotrons; Accelerators; Instruments and Techniques
local.identifier.ariespublicationu9210271xPUB475
local.identifier.citationvolume7804
local.identifier.doi10.1117/12.860285
local.identifier.scopusID2-s2.0-78649430525
local.identifier.thomsonID000287816200016
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Kingston_An_auto-focus_method_for_2010.pdf
Size:
4.39 MB
Format:
Adobe Portable Document Format