Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Frequency doubling illlusion VEPs and automated perimetry in multiple sclerosis

dc.contributor.authorRuseckaite, Rasa
dc.contributor.authorMaddess, Ted
dc.contributor.authorDanta, Gytis
dc.contributor.authorJames, Andrew
dc.date.accessioned2015-12-08T22:20:25Z
dc.date.issued2006
dc.date.updated2015-12-08T08:30:25Z
dc.description.abstractWe examined frequency doubling (FD) illusion based automated perimetry (FDT) and dichoptic FD multifocal visual evoked potentials (FDmfVEPs) in Normal and multiple sclerosis (MS) subjects. Contrast thresholds were determined at 17 visual field locations using an FDT perimeter. The stimuli presented to each location were 0.25 cpd gratings presented with rapid (25 Hz) counterphase flicker and thus displayed the spatial FD illusion. Dichoptic mfVEPs were recorded by concurrently stimulating eight regions/eye with FD stimuli presented at 95% contrast. Recordings were obtained from 27 Normal subjects, 26 MS patients who had experienced Optic Neuritis (MSON) and 24 MS patients without a history of ON (MSNON). The FDT thresholds showed enhanced contrast sensitivity for MSON patients (P < 0.0001) but not for MSNON patients. Response amplitudes for the central four regions of the mfVEP stimulus were reduced in both patient groups (P < 0.005). A classification model based upon the FDT thresholds performed at a specificity of 96% for a sensitivity of 97% in MSON patients, but the accuracy (simultaneously largest sensitivities and specificities) was poor (∼60%) in MSNON patients. Discriminant models based on the FDT thresholds and FDmfVEPs were able to diagnose more that 90% MSON patients but performed poorly for MSNON patients.
dc.identifier.issn0012-4486
dc.identifier.urihttp://hdl.handle.net/1885/31985
dc.publisherSpringer
dc.sourceDocumenta Ophthalmologica
dc.subjectKeywords: adult; amplitude modulation; article; automation; contrast sensitivity; controlled study; critical flicker fusion; diagnostic accuracy; diagnostic value; evoked visual response; female; human; major clinical study; male; multiple sclerosis; optic neuritis Frequency doubling illusion; Multiple sclerosis; Optic neuritis; ROCs
dc.titleFrequency doubling illlusion VEPs and automated perimetry in multiple sclerosis
dc.typeJournal article
local.bibliographicCitation.lastpage41
local.bibliographicCitation.startpage29
local.contributor.affiliationRuseckaite, Rasa, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationMaddess, Ted, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationDanta, Gytis, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationJames, Andrew, College of Medicine, Biology and Environment, ANU
local.contributor.authoruidRuseckaite, Rasa, u4020780
local.contributor.authoruidMaddess, Ted, u8103614
local.contributor.authoruidDanta, Gytis, a200360
local.contributor.authoruidJames, Andrew, u8607703
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor110904 - Neurology and Neuromuscular Diseases
local.identifier.absfor110906 - Sensory Systems
local.identifier.ariespublicationu9204316xPUB87
local.identifier.citationvolume113
local.identifier.doi10.1007/s10633-006-9011-3
local.identifier.scopusID2-s2.0-33748690313
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Ruseckaite_Frequency_doubling_illlusion_2006.pdf
Size:
463.7 KB
Format:
Adobe Portable Document Format