Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Precision analysis of single-element ultrasound sensor for kinematic analysis of knee joints

dc.contributor.authorMasum, M A
dc.contributor.authorPickering, Mark
dc.contributor.authorLambert, Andrew John
dc.contributor.authorSmith, Paul
dc.contributor.authorScarvell, J N
dc.date.accessioned2015-12-10T23:33:21Z
dc.date.issued2014
dc.date.updated2015-12-10T11:27:37Z
dc.description.abstractMeasuring the relative motion of the femur and tibia in a knee joint currently requires tantalum beads to be implanted into the bones. These beads appear as high-intensity features in radiographs and can be used for precise kinematic measurements. This procedure imposes a strong coupling between accuracy and invasiveness. Advances in ultrasound (US) sensor technology and the availability of micro-drives mean that it is now possible to construct a small and lightweight US sensor which can be placed on the skin above the tibia and femur. Such a sensor could determine the relative movement of the underlying bone with respect to the sensor. This would then allow the position of the femur and tibia to be measured more accurately than with an optical tracking system that does not take into account the movement of the marker with respect to the bone. For satisfactory performance, the precision of the US sensor should be in the order of 1 mm or less. The experimental results prove that this sub-millimetre precision is achievable.
dc.identifier.issn0013-5194
dc.identifier.urihttp://hdl.handle.net/1885/69259
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE Inc)
dc.sourceElectronics Letters
dc.titlePrecision analysis of single-element ultrasound sensor for kinematic analysis of knee joints
dc.typeJournal article
local.bibliographicCitation.issue15
local.bibliographicCitation.lastpage1048
local.bibliographicCitation.startpage1047
local.contributor.affiliationMasum, M A, University of New South Wales
local.contributor.affiliationPickering, Mark, University of New South Wales, ADFA
local.contributor.affiliationLambert, Andrew John, University of New South Wales, ADFA
local.contributor.affiliationSmith, Paul, College of Medicine, Biology and Environment, ANU
local.contributor.affiliationScarvell, J N, The Canberra Hospital
local.contributor.authoruidSmith, Paul, u1496431
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor110314 - Orthopaedics
local.identifier.ariespublicationa383154xPUB1972
local.identifier.citationvolume50
local.identifier.doi10.1049/el.2014.1230
local.identifier.scopusID2-s2.0-84904325318
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Masum_Precision_analysis_of_2014.pdf
Size:
226.05 KB
Format:
Adobe Portable Document Format