Calibrating Focused Light-Field Cameras Using Plenoptic Disc Features

dc.contributor.authorO’Brien, Sean G. P.
dc.contributor.authorTrumpf, Jochen
dc.contributor.authorIla, Viorela
dc.contributor.authorMahony, Rob
dc.date.accessioned2021-04-14T05:18:30Z
dc.date.available2021-04-14T05:18:30Z
dc.date.issued2019
dc.description.abstractThis paper proposes a new method for estimating calibration parameters of plenoptic cameras by minimizing the nonlinear plenoptic reprojection error. Novel plenoptic feature types are proposed as data for the calibration method. These plenoptic disc features are in a natural one-to-one correspondence with physical points in front of the camera. We exploit the intrinsic geometry of plenoptic cameras in a novel projection model that relates the plenoptic disc features to physical points. The resulting calibration quality, as quantified by mean reprojection error and 3D reconstruction error, outperforms recently published results.en_AU
dc.format.mimetypeapplication/pdfen_AU
dc.identifier.urihttp://hdl.handle.net/1885/229865
dc.language.isoen_AUen_AU
dc.publisherInternational Conference on 3DVisionen_AU
dc.relation.ispartofInternational Conference on 3DVision, Verona, Italy, September 5-8, 2018en_AU
dc.rights© 2018 The Author(s)en_AU
dc.titleCalibrating Focused Light-Field Cameras Using Plenoptic Disc Featuresen_AU
dc.typeConference paperen_AU
dcterms.accessRightsOpen Accessen_AU
local.bibliographicCitation.lastpage9en_AU
local.bibliographicCitation.startpage1en_AU
local.contributor.affiliationO’Brien, S., Research School of Engineering, The Australian National Universityen_AU
local.contributor.affiliationTrumpf, J., Research School of Engineering, The Australian National Universityen_AU
local.contributor.affiliationIla, V., Research School of Engineering, The Australian National Universityen_AU
local.contributor.affiliationMahony, R., Research School of Engineering, The Australian National Universityen_AU
local.contributor.authoremailu4846794@anu.edu.auen_AU
local.contributor.authoruidu4846794en_AU
local.identifier.uidSubmittedByu1005913en_AU
local.publisher.urlhttp://3dv18.uniud.it/program.htmlen_AU
local.type.statusPublished Versionen_AU

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2018 Calibrating Focused Light-Field Cameras Using Plenoptic Disc Features_Jochen Trumpf.pdf
Size:
2.77 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
884 B
Format:
Item-specific license agreed upon to submission
Description: