Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

High brightness inductively coupled plasma source for high current focused ion beam applications

Loading...
Thumbnail Image

Authors

Smith, N. S.
Skoczylas, W. P.
Kellogg, S. M.
Kinion, D. E.
Tesch, P. P.
Sutherland, O.
Aanesland, Ane
Boswell, R. W.

Journal Title

Journal ISSN

Volume Title

Publisher

American Institute of Physics (AIP)

Abstract

A high brightnessplasmaion source has been developed to address focused ion beam(FIB) applications not satisfied by the liquid metal ion source (LMIS) based FIB. The plasmaFIB described here is capable of satisfying applications requiring high mill rates (>100μm³/s) with non-gallium ions and has demonstrated imaging capabilities with sub- 100-nm resolution. The virtual source size, angular intensity, mass spectra, and energy spread of the source have been determined with argon and xenon. This magnetically enhanced, inductively coupled plasmasource has exhibited a reduced brightness(βr) of 5.4×10³Am⁻²sr⁻¹V⁻¹, with a full width half maximum axial energy spread (ΔE) of 10eV when operated with argon. With xenon, βr=9.1×10³Am⁻²sr⁻¹V⁻¹ and ΔE=7eV. With these source parameters, an optical column with sufficient demagnification is capable of forming a sub-25-nm spot size at 30keV and 1pA. The angular intensity of this source is nominally three orders of magnitude greater than a LMIS making the source more amenable to creating high current focused beams, in the regime where spherical aberration dominates the LMIS-FIB. The source has been operated on a two lens ion column and has demonstrated a current density that exceeds that of the LMIS-FIB for current greater than 50nA. Source lifetime and current stability are excellent with inert and reactive gases. Additionally, it should be possible to improve both the brightness and energy spread of this source, such that the (βr/ΔE₂) figure-of-merit could be within an order of magnitude of a LMIS.

Description

Citation

Source

Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures

Book Title

Entity type

Access Statement

License Rights

Restricted until

Downloads