Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Optimizing LA-ICP-MS analytical procedures for elemental depth profiling of foraminifera shells

Loading...
Thumbnail Image

Date

Authors

Fehrenbacher, Jennifer S
Spero, Howard
Russell, Ann
Vetter, Lael
Eggins, Stephen

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is becoming a widespread technique for analyzing elemental ratios in foraminiferal calcite. Here we focus on optimizing LA-ICP-MS for high-resolution depth profiling of elemental ratios through shell walls. This application reveals intrashell variability and provides a unique opportunity to quantify trace element incorporation over short time scales of calcification by an individual foraminifer. High-resolution depth profiling requires careful consideration of both ablation and analytical conditions required to resolve differences in shell chemistry across sub-micron shell thickness. We present laser ablation profiles of NIST SRM 610 standard glass data (in cps) and elemental/Ca ratios (in mmol/mol) from foraminiferal calcite obtained over a range of operating conditions using a Photon Machines 193nm UV excimer laser-ablation system, equipped with a dual-volume ANU HelEx chamber, coupled to an Agilent 7700x quadrupole ICP-MS. Different combinations of energy density, repetition rate, and mass spectrometer cycle time can yield varying elemental profiles. This variability can mimic and/or mask real intrashell trace element heterogeneity in foraminifer shells. At low (<3Hz) laser repetition rates, real intrashell element variation can be obscured depending on the laser energy, whereas using moderate (≥3Hz) laser repetition rates and/or a signal-smoothing device improves the accuracy and precision of intrashell trace element profiles. Shell material is ablated rapidly when using a 5Hz or greater repetition rate and an energy density of 3J/cm2 or greater, resulting in reduced spatial resolution.

Description

Keywords

Citation

Source

Chemical Geology

Book Title

Entity type

Access Statement

License Rights

Restricted until

2037-12-31