Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Iodine staining outperforms phosphotungstic acid in high-resolution micro-CT scanning of post-natal mice cardiac structures

Loading...
Thumbnail Image

Date

Authors

Doost, Ata
Arnolda, Leonard

Journal Title

Journal ISSN

Volume Title

Publisher

S P I E - International Society for Optical Engineering

Abstract

Purpose: Micro-computed tomography (micro-CT) scan provides high-resolution three-dimensional images of mineralized tissues in small animal models. Contrast enhancement is essential to visualize non-mineralized tissues with micro-CT scan. We attempted to compare the two most common contrast agents to stain and image mouse cardiac structures. Approach: Ex-vivo micro-CT scan images of the mouse hearts were obtained following staining by potassium iodide or phosphotungstic acid (PTA). PTA-stained samples were imaged after various durations following staining (14 days, 25 days, 187 days, and 780 days), whereas iodine-stained samples were imaged after 72 hours. We compared median staining intensity between PTA and iodine at 0.1-mm intervals from the edge using the Mann Whitney test with correction for multiple comparisons. Results: Sixty post-natal mice hearts were stained with either PTA or iodine and imaged using micro-CT scan. Iodine proved to be faster and more uniform in complete enhancement of cardiac tissue in as short as 72 h, whereas PTA required a significantly longer time period to penetrate mouse cardiac structure (>150  days). Median staining intensity with iodine was strongly higher than that with PTA from 0.1- to 1.5-mm distance from the epicardial edge (2-tailed P value <0.01 or lower throughout). Conclusions: Iodine-stained soft tissue imaging by micro-CT scan provides a non-destructive, efficient, and accurate visualization tool for anatomical analysis of animal heart models of human cardiovascular conditions. Iodine is more efficient compared to PTA to achieve complete murine myocardial staining in a significantly shorter time period.

Description

Citation

Source

Journal of Medical Imaging

Book Title

Entity type

Access Statement

Open Access

License Rights

Restricted until