Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Hybrid additive manufacturing of biocompatible Ti–Ta composite structures for biomedical applications

dc.contributor.authorZeng, Guangen
dc.contributor.authorZahiri, Saden H.en
dc.contributor.authorGulizia, Stefanen
dc.contributor.authorChen, Yapingen
dc.contributor.authorChen, Xiao Boen
dc.contributor.authorCole, Ivanen
dc.date.accessioned2026-07-03T22:40:37Z
dc.date.available2026-07-03T22:40:37Z
dc.date.issued2021-09-28en
dc.description.abstractRapid advances in 3D hybrid additive manufacturing have provided opportunities to the use of Ta as a highly effective biomaterial. In this study, we used electron beam melting (EBM) process to fabricate Ti–6Al–4V 3D structures (EBM-Ti64) and then applied cold spray additive manufacturing to deposit commercially pure (CP) Ti, Ti–Ta composite and pure Ta coatings on the EBM-Ti64 substrate to explore the biocompatibility of Ti–Ta composite structures through hybrid additive manufacturing. The microstructure, microhardness, corrosion resistance and biocompatibility were evaluated. Feedstock powders and process parameters of cold spray determine the microstructures of the deposited coating. Microhardness and indentation testing of Ti–Ta composite reveal the weight ratio of Ta influences the microhardness. In particular, higher corrosion resistance was achieved on cold sprayed Ti–30%Ta composite compared to CP Ti and pure Ta coatings. Moreover, live/dead and MTS assay demonstrate that the cold sprayed coatings were non-toxic, while the EBM-Ti64 substrate shows some cytotoxicity signs which might be related to the released toxic ions. This study confirms the biocompatible Ti–Ta composite structures can be manufactured through a combination of EBM and cold spray, opening opportunities for the rapid hybrid manufacture of biocompatible implants. Graphic abstract: [Figure not available: see fulltext.].en
dc.description.sponsorshipThe authors would like to thank the facilities, scientific and technical assistance of the Australian Microscopy & Microanalysis Research Facilities (AMMRF), MicroNano Research Facility (MNRF) at RMIT University and the Cold Spray Laboratory at CSIRO. The authors also acknowledge the scientific assistance of Dr Zeyad Nasa, Dr Adam Truskewycz and Mr Qiushi Deng from RMIT University and Dr Alejandro Vargas Uscategui, Mr David Ritchie, Dr Darren Fraser, Mr Andrew Urban, Dr Lathabai Sri, Mrs Jessica Andrade, Dr Veronica Glattauer, Dr Malisja de Vries and Mr Mark Greaves from CSIRO. G.Z. acknowledges the support through “Australian Government Research Training Program Scholarship” and RMIT Research Stipend Scholarship. This work was performed partially at the Melbourne Centre for Nanofabrication (MCN) at Victorian Node of the Australian National Fabrication Facility (ANFF). The authors would like to thank the facilities, scientific and technical assistance of the Australian Microscopy & Microanalysis Research Facilities (AMMRF), MicroNano Research Facility (MNRF) at RMIT University and the Cold Spray Laboratory at CSIRO. The authors also acknowledge the scientific assistance of Dr Zeyad Nasa, Dr Adam Truskewycz and Mr Qiushi Deng from RMIT University and Dr Alejandro Vargas Uscategui, Mr David Ritchie, Dr Darren Fraser, Mr Andrew Urban, Dr Lathabai Sri, Mrs Jessica Andrade, Dr Veronica Glattauer, Dr Malisja de Vries and Mr Mark Greaves from CSIRO. G.Z. acknowledges the support through “Australian Government Research Training Program Scholarship” and RMIT Research Stipend Scholarship. This work was performed partially at the Melbourne Centre for Nanofabrication (MCN) at Victorian Node of the Australian National Fabrication Facility (ANFF).en
dc.description.statusPeer-revieweden
dc.format.extent12en
dc.identifier.issn0884-2914en
dc.identifier.otherORCID:/0000-0001-6582-1457/work/219176285en
dc.identifier.scopus85104555566en
dc.identifier.urihttps://hdl.handle.net/1885/733812502
dc.language.isoenen
dc.rightsPublisher Copyright: © 2021, The Author(s), under exclusive licence to The Materials Research Society.en
dc.sourceJournal of Materials Researchen
dc.subjectCold sprayen
dc.subjectEBMen
dc.subjectHybrid additive manufacturingen
dc.subjectTi–Ta composite structuresen
dc.titleHybrid additive manufacturing of biocompatible Ti–Ta composite structures for biomedical applicationsen
dc.typeJournal articleen
dspace.entity.typePublicationen
local.bibliographicCitation.lastpage3690en
local.bibliographicCitation.startpage3679en
local.contributor.affiliationZeng, Guang; Royal Melbourne Institute of Technology Universityen
local.contributor.affiliationZahiri, Saden H.; CSIROen
local.contributor.affiliationGulizia, Stefan; CSIROen
local.contributor.affiliationChen, Yaping; CSIROen
local.contributor.affiliationChen, Xiao Bo; Royal Melbourne Institute of Technology Universityen
local.contributor.affiliationCole, Ivan; Royal Melbourne Institute of Technology Universityen
local.identifier.citationvolume36en
local.identifier.doi10.1557/s43578-021-00190-wen
local.identifier.pureff4ec35f-c165-4e83-9ca0-a4eeba72870ben
local.identifier.urlhttps://www.scopus.com/pages/publications/85104555566en
local.type.statusPublisheden

Downloads

abcd