Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Capillary circular dichroism

Loading...
Thumbnail Image

Date

Authors

Waldron, Daniel E.
Marrington, Rachel
Grant, Marcus C.
Hicks, Matthew R.
Rodger, Alison

Journal Title

Journal ISSN

Volume Title

Publisher

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

Circular dichroism (CD) has become an increasingly important tool in the study of biological molecules as it enables structural information to be obtained nondestructively on solution-phase samples. However, sample requirements for CD are often seen as being too high with protein backbone measurements in standard cuvettes typically requiring ∼100300 μL of 0.1 mg/ml protein. To address this issue, we have designed a new form of CD sample holder, which reduces the sample requirements of the technique by two orders of magnitude, with a sample requirement of less than 3 μl. This sample saving has been achieved through the use of extruded quartz capillaries, the sample being held within the internal diameter of the quartz capillary through capillary action. The extruded quartz capillaries exhibit remarkably little birefringence, although still transmitting high energy UV circularly polarized light. The optics associated with capillaries were investigated. A configuration has been adopted with the light beam of the spectrophotometer being focused in front of the front face of the capillary using a biconvex lens and advantage being taken of the additional focusing effect of the capillary itself. The focusing is vital to the low wavelength performance of the cell, where we have acquired reliable data down to 180 nm using a Jasco J-815 spectrophotometer. The system performance was validated with Na[Co(EDDS)].H2O (EDDS = N,N-ethylenediaminedisuccinic acid), concanavalin A, lysozyme, and progesterone. Chirality, 2010. © 2010 Wiley-Liss, Inc. ©

Description

Citation

Source

Chirality

Book Title

Entity type

Publication

Access Statement

License Rights

Restricted until

abcd