Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Stability and locality of amplitude and phase contrast tomographies

dc.contributor.authorGureyev, Timur E.en
dc.contributor.authorMyers, Glenn R.en
dc.contributor.authorNesterets, Yakov I.en
dc.contributor.authorPaganin, David M.en
dc.contributor.authorPavlov, Konstantin M.en
dc.contributor.authorWilkins, Stephen W.en
dc.date.accessioned2025-06-24T08:38:35Z
dc.date.available2025-06-24T08:38:35Z
dc.date.issued2006en
dc.description.abstractWe perform a theoretical analysis of the mathematical stability and locality of several modes of amplitude and phase contrast computed tomography (CT) suitable for reconstruction of the 3D distribution of complex refractive index in samples displaying weak absorption contrast. We present a general formalism for CT reconstruction in linear shiftinvariant optical systems. Examples of such systems include propagation-based and analyser-based CT. We obtain general formulae for CT reconstruction from analyser-based projection data. We also propose a new tomographic algorithm for the reconstruction of the 3D distribution of complex refractive index in a sample from a single propagation-based projection image per view angle, where the images display both absorption and phase contrast. The method assumes that the real and imaginary parts of the refractive index are proportional to each other. Using singularvalue decompositions of the relevant operators we show that, in contrast to conventional amplitude-contrast CT, phasecontrast (diffraction) tomography is mathematically well-posed. The presented results are pertinent to biomedical imaging and non-destructive testing of samples exhibiting weak absorption contrast.en
dc.description.statusPeer-revieweden
dc.identifier.isbn0819463973en
dc.identifier.isbn9780819463975en
dc.identifier.issn1605-7422en
dc.identifier.otherORCID:/0000-0003-4444-8731/work/162951956en
dc.identifier.scopus33750688210en
dc.identifier.urihttp://www.scopus.com/inward/record.url?scp=33750688210&partnerID=8YFLogxKen
dc.identifier.urihttps://hdl.handle.net/1885/733764824
dc.language.isoenen
dc.relation.ispartofDevelopments in X-Ray Tomography Ven
dc.relation.ispartofseriesDevelopments in X-Ray Tomography Ven
dc.relation.ispartofseriesProgress in Biomedical Optics and Imaging - Proceedings of SPIEen
dc.subjectComputed tomographyen
dc.subjectDiffractionen
dc.subjectPhase contrasten
dc.titleStability and locality of amplitude and phase contrast tomographiesen
dc.typeConference paperen
dspace.entity.typePublicationen
local.contributor.affiliationGureyev, Timur E.; CSIROen
local.contributor.affiliationMyers, Glenn R.; Research School of Physics, ANU College of Science and Medicine, The Australian National Universityen
local.contributor.affiliationNesterets, Yakov I.; CSIROen
local.contributor.affiliationPaganin, David M.; Monash Universityen
local.contributor.affiliationPavlov, Konstantin M.; Monash Universityen
local.contributor.affiliationWilkins, Stephen W.; CSIROen
local.identifier.doi10.1117/12.680185en
local.identifier.pured6bee45e-c2d0-4c43-861d-edcd63b84836en
local.identifier.urlhttps://www.scopus.com/pages/publications/33750688210en
local.type.statusPublisheden

Downloads