Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

High voltage performance degradation of the 14ud tandem accelerator

Loading...
Thumbnail Image

Authors

Linardakis, P.
Lobanov, N. R.
Tunningley, T. B.
Tsifakis, D.
Battisson, S. T.
Graham, B.
Bockwinkel, J. A.
Heighway, J.

Journal Title

Journal ISSN

Volume Title

Publisher

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

The 14UD at the Australian National University's Heavy Ion Accelerator Facility (HIAF) operated at a maximum voltage of 15.5 MV after the installation of tubes with a compressed geometry in the 1990s. In recent years, the performance of the accelerator has shown a gradual decline to a maximum operation voltage of ∼14.5 MV. There are some fundamental factors that limit the high voltage performance, such as SF6 gas pressure, field enhancement due to triple junctions and total voltage effect. In addition, there are non-fundamental factors causing high voltage degradation. These are: operation with faulty ceramic gaps; operation at inappropriate voltage and SF6 pressure combinations; SF6 leaks into the vacuum space; use of SF6 and O2 as a stripper gases; poor electron suppression in the high energy stripper and frequent use of highly reactive ions such as sulphur and fluorine. In this paper we will discuss factors that limit the high voltage performance. The main outcomes of a preliminary investigation of titanium (Ti) electrodes removed from the accelerator after a few decades of operation will be reported. The investigation confirmed contamination of Ti electrodes with unstable films containing traces of oxides, sulphur and fluorine. The rehabilitation strategies for the accelerator will be discussed.

Description

Keywords

Citation

Source

Journal of Physics: Conference Series

Book Title

Entity type

Publication

Access Statement

License Rights

Restricted until