Investigating the effect of water content in supercritical CO<sub>2</sub> as relevant to the corrosion of Carbon capture and storage pipelines
Loading...
Date
Authors
Sim, S.
Bocher, F.
Cole, I. S.
Chen, X. B.
Birbilis, N.
Journal Title
Journal ISSN
Volume Title
Publisher
Access Statement
Abstract
Steel coupons were exposed to a supercritical carbon dioxide (CO2) environment in which water contamination was deliberately added over the range from 100 ppmw to 50,000 ppmw. Exposure was carried out in a laboratory scale autoclave at 8 MPa and 40°C for 7 days. Contaminant water inCO 2permits the speciation of carbonic acid (H2CO 3), which can itself be a threat to durability, but also permit further contaminants to segregate to the aqueous acid phase. A systematic investigation of corrosion in supercriticalCO2over a range of water concentrations is lacking in the literature, despite being a significant elementary issue. Herein, weight-loss tests were performed, and subsequent scanning electron microscopy suggested all specimens displayed some extent of corrosion. The main corrosion mechanism observed was uniform corrosion. Supplementary optical profilometry suggested that water concentration has a small effect on any pitting corrosion that occurred. In general, increased mass loss was observed with an increase in water concentration beyond 1,000 ppmw H2O, concomitant with a rate of change in the H2CO 3 concentration.
Description
Citation
Collections
Source
Corrosion