Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

A new reference material for UV-visible circular dichroism spectroscopy

Loading...
Thumbnail Image

Date

Authors

Damianoglou, Angeliki
Crust, Edward J.
Hicks, Matthew R.
Howson, Suzanne E.
Knight, Alex E.
Ravi, Jascindra
Scott, Peter
Rodger, Alison

Journal Title

Journal ISSN

Volume Title

Publisher

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

To obtain accurate and consistent measurements from circular dichroism (CD) instruments over time and from different laboratories, it is important that they are properly calibrated. The characteristics of the available reference materials are not ideal to ensure proper calibration as they typically only give peaks in one or two spectral regions, and often have issues concerning purity and stability. Currently either camphor sulfonic acid or ammonium camphor sulfonate are used. The latter can be an unstable, slightly hygroscopic secondary standard compound with only one characterized CD band. The former is the very hygroscopic primary standard for which only one enantiomer is readily available. We have synthesized a new reference material for CD, Na[Co(EDDS)]· H2O (EDDS = N,N-ethylenediaminedisuccinic acid) which addresses these problems. It is extremely stable and available in both enantiomeric forms. The CD spectrum of Na[Co(EDDS)]·H2O has nine distinct peaks between 180 and 599 nm. It thus fulfils the principal requirements for CD calibration chemical standards and has the potential to be used to ensure good practice in the measurement of CD data, providing two spectra of equal magnitude and opposite sign for a given concentration and path length. We have carried out an interlaboratory comparison using this material and show how it can be used to improve CD comparability between laboratories. A fitting algorithm has been developed to assess CD spectropolarimeter performance between 750 and 178 nm. This could be the basis of a formal quality control process once criteria for performance have been decided.