Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Electrocardiographic Characteristics and Ablation Outcomes Associated With Para-Hisian Ventricular Arrhythmias

Loading...
Thumbnail Image

Date

Authors

Nair, Anugrah
Shroff, Jenish P.
Tuan, Lukah Q.
Tokich, Adriana
Raja, Deep Chandh
Mehta, Abhinav
Abhayaratna, Walter P.
Sanders, Prashanthan
Marchlinski, Francis E.
Shivkumar, Kalyanam

Journal Title

Journal ISSN

Volume Title

Publisher

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

Background: Ventricular arrhythmias (VAs) near the His-bundle comprise 9% of unexplained VAs and present challenges for ablation caused by the risk of atrioventricular block. Objectives: The authors studied the electrocardiographic (ECG) and electrophysiological characteristics of Para-Hisian (PH) VAs, comparing them with septal right ventricular outflow tract VAs. Methods: From 210 patients with VAs between 2018 and 2024, 31 (14.7%) with PH-VAs and 23 (10.9%) with septal right ventricular outflow tract VAs were included. ECG characteristics of both were compared, and features differentiating left and right PH and supra- and infra-Hisian VAs were identified. Results: Of 31 patients, 15 had VAs from the right PH site and 16 from the left. Median follow-up was 15 months (Q1-Q3: 14-21 months) for left infra-Hisian, 16 months (Q1-Q3: 14-20 months) for left supra-Hisian, and 14 months (Q1-Q3: 14-16 months) for right infra-Hisian and right supra-Hisian VAs (Q1-Q3: 14-15 months). PH-VAs had narrower QRS complexes (134 ± 19.6 ms vs 169 ± 24 ms; P < 0.05), R-wave in lead aVL (100% [31 of 31] vs 4.3% [1 of 23]; P < 0.001), and earlier R-wave transition at or before lead V3 (80.6% [25 of 31] vs 47.8% [11 of 23]; P < 0.05). Left PH-VAs had earlier R-wave transition at lead V2 (50% [8 of 16] vs 20% [3 of 15]; P = 0.036). Right PH VAs had deeper S-wave relative to the preceding sinus beat in lead V1 (73.3% [11 of 15] vs 37.5% [6 of 16]; P = 0.04) and lead aVR (80% [12 of 15] vs 56.3% [9 of 16]; P = 0.01). Postprocedure heart block occurred in 1 patient. Conclusions: PH-VAs exhibit unique ECG features based on their origins, and can be effectively treated without affecting atrioventricular conduction.

Description

Citation

Source

JACC: Asia

Book Title

Entity type

Publication

Access Statement

License Rights

Restricted until

Downloads