Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Augmenting cavity receiver performance: Spillage skirts and secondary reflectors

Loading...
Thumbnail Image

Authors

Wang, Shuang
Asselineau, Charles Alexis
Pye, John
Coventry, Joe

Journal Title

Journal ISSN

Volume Title

Publisher

American Institute of Physics Inc.

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

In this study, Monte Carlo ray tracing (MCRT) is coupled with heat transfer models to analyse the efficiencies and energy losses of a cylindrical cavity receiver in a dish system. The progressive Monte Carlo evaluation (PMCE) method is used to determine good geometric designs with high receiver efficiencies. The spillage skirt, which consists of several coiled pipes outside the cavity inlet, is added and optimised to increase the receiver efficiency. Three different types of secondary reflectors, including conical, trumpet and compound parabolic concentrator (CPC) reflectors are also investigated to decrease the spillage loss. The results show that the spillage skirt helps in greatly decreasing the aperture size, while simultaneously reducing the spillage loss. The conical and trumpet reflectors can increase the efficiency by reflecting rays outside the cavity inlet into the receiver. CPC secondary reflectors experience more internal reflections which cause high secondary absorption loss and consequently cannot achieve the equivalent efficiency compared to other designs. With a combination of spillage skirt and conical or trumpet reflectors, the receivers obtain the highest efficiency, with a 1.0% increment in receiver efficiency and 12.9% relative reduction of losses compared to the best cylindrical receiver. Limitations of the current study are that the effects of skirt and reflectors on convective losses are not considered and that the primary concentrator design is fixed.